Beha-Amprobe Telaris Série Guide D'utilisation page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
Terminal indicator symbol. A terminal indicator symbol with a dot (O) in the
center indicates the terminal is used for the selected function. The terminals
are:
24
• L (Line)
• PE (Protective Earth)
• N (Neutral)
Indicates the selected rotary switch setting. The measurement value in the
primary display also corresponds to the switch setting. Rotary switch settings are:
25
Indicates the preset fault voltage limit. The default setting is 50 V. Some
locations require the fault voltage be set to 25 V, as specified by local electrical
26
codes. Press F4 when you turn on the tester to toggle the fault voltage
between 25 V and 50 V. The value you set will appear on the display and will be
saved when you turn the tester off.
27
Primary display and measurement units.
Memory locations. See page 37 for detailed information on using memory
28
locations.
Low battery icon. See "Testing and Replacing the Batteries" on page 41 for
29
additional information on batteries and power management.
30
Appears when you press the Recall button and you are looking at stored data.
31
Appears when you press the Memory button.
Appears when you press the Test button. Disappears when the test is
32
completed.
Appears when the instrument is overheated. The Loop test and RCD functions
33
are inhibited when the instrument is overheated.
Appears when an error occurs. Testing is disabled. See "Error Codes" on page
34
16 for a listing and explanation of possible error codes.
35
Appears when the instrument is uploading data using Amprobe PC software.
Name of the secondary measurement function.
U
- Test voltage for insulation test.
N
36
U
- Fault voltage. Measures neutral to earth.
F
PSC - Prospective Short Circuit. Calculated from measured voltage and impedance
Secondary display and measurement units. Some tests will return more than
one result or return a computed value based on the test result. This will occur
with:
37
• Volts • RCD switching time
• Insulation tests • RCD tripping current
• Loop / line impedance
38
Press F3 to compensate the test lead for the continuity function.
39
Appears when a compensation value for the test exists.
40
Potential danger. Appears when measuring or sourcing high voltages.
Insulation
Continuity
Loop no trip
Loop hi current trip
7
RCD trip time
RCD trip current
Earth
Phase Rotation

Publicité

Table des Matières
loading

Table des Matières