State Of California Proposition 65 Warnings; Causes For Damages; Protecting The Environment; General Notes - Bosch HCP34E51UC Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

State of California Proposition 65
Warnings
WARNING
This product contains chemicals known to the State of
California to cause cancer, birth defects or other
reproductive harm.

Causes for damages

CAUTION
Risk of damage due to corrosion. Always turn
appliance on when cooking to avoid condensation
buildup. Condensation can lead to corrosion
damages.
Always replace defective bulbs immediately to avoid an
overload of the remaining bulbs.

Protecting the environment

Unpack the appliance and dispose of the packaging in line
with environmental requirements.

General notes

Fan operation

Note: Ventilation may not exit through an already
operational smoke or exhaust chimney, nor a duct used for
ventilating furnace installation areas.
If the ventilation is intended to pass through a smoke or
exhaust that is not in operation, the responsible area
heating inspector must give approval.
If the ventilation passes through an external wall, use a
telescope wall sleeve.

Ventilation line

Note: The manufacturer does not assume any warranty for
complaints attributable to the pipe section.
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as large
a pipe diameter as possible.
The optimum extraction performance is not achieved
and fan noise is increased if exhaust air pipes are long
and rough and if there is a large number of pipe bends
or diameters less than 5 15/ia" (150 mm).
8
Risk of damage due to ingress of humidity into the
electronic circuitry. Never clean operator controls with a
wet cloth.
Surface damage due to incorrect cleaning. Clean stainless
steel surfaces in the grind direction only. Do not use any
stainless steel cleaners for operator controls.
Never use strong or abrasive cleaning agents, since they
can cause surface damage.
Risk of damage from condensation back flow. Install
exhaust vent at a slight downward slope away from the
appliance (1° slope).
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes
15
An inner diameter of 5
(120 mm), is recommended.
Flat ducts
The inner cross-section must correspond to the diameter
of the round pipes.
15
Ø 5
/
" (150 mm) approx. 27
16
3
Ø 4
/
" (120 mm) approx. 17
4
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.
/
" (150 mm), but at least 4
16
1
2
/
sq in (177 cm
2
1
2
/
sq in (113 cm
)
2
3
/
"
4
)

Publicité