5.3.1 - CUT-OUT SWITCH (Only the United States)

This UL version high-pressure washer is equipped with a cut-out switch contained in the power
cable plug.
Said equipment provides extra protection against the risk of electric shock.
When replacing the plug or cable, use the same components including the cut-out device.
5.4 - USE OF CORDS
If an extension cord is used, make sure that plug and receptacle are of a water-tight type. In
any case they must be raised from the ground in order to avoid possible contact with water.
Use only extension cables with the same number of conductors as those of the machine cable,
including the earthing cable, and with a suitable plug/socket for the cable used.
Only use extension cords for outdoor use. Said type of cable is marked "Suitable for outdoor
use." Store inside when not in use.
Do not use damaged extension cords. Cables should not be located near sources of heat or
sharp edges. Always disconnect the plug from the socket before removing the extension cord
from the product. Do not pull the cable to pull the plug out of the outlet. Do not touch the plug
or connections with wet hands.
USE OF INADEQUATE
EXTENSION CORDS
MAY CAUSE SAFETY
WARNING
HAZARDS
SELECTION TABLE
Extension
Voltage
cord length
Up to 20 m
230÷240
From 20 to 50 m
230÷240
Up to 50 m
400÷415
11
Cord section
mm
2
2,5
4
2,5