Cut-Out Switch (Only The United States) - Interpump Group IPX Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26

5.3.1 - CUT-OUT SWITCH (Only the United States)

This UL version high-pressure washer is equipped with a cut-out switch contained in the power
cable plug.
Said equipment provides extra protection against the risk of electric shock.
When replacing the plug or cable, use the same components including the cut-out device.
5.4 - USE OF CORDS
If an extension cord is used, make sure that plug and receptacle are of a water-tight type. In
any case they must be raised from the ground in order to avoid possible contact with water.
Do not use damaged extension cords. Cables should not be located near sources of heat or
sharp edges. Always disconnect the plug from the socket before removing the extension cord
from the product. Do not pull the cable to pull the plug out of the outlet. Do not touch the plug
or connections with wet hands.
USE OF INADEQUATE
EXTENSION CORDS
MAY CAUSE SAFETY
WARNING
HAZARDS
SELECTION TABLE
Extension
Voltage
cord length
Up to 20 m
230÷240
From 20 to 50 m
230÷240
Up to 50 m
400÷415
15
Cord section
mm
2
2,5
4
2,5

Publicité