Oil Capacity; Replacement Of High Pressure Nozzle - Interpump Group IPX Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
IP SERIES

Oil capacity:

• Unscrew the dipstick/discharge plug situated on the pump.
• Empty oil from the pump into a container.
This must later be delivered to an authorised collection centre.
• Pour in the quantity of oil indicated depending on the model.
• Screw in the dipstick/discharge plug.
IP
10.2 - FILTER SUCTION
Before using the machine it is IMPORTANT to make sure that the filter is clean. Wash the fil-
ter under running water and/or with an air pressure gun to totally eliminate any deposits in the
filter.
Remember that a clean filter guarantees the good of the machine operation.
IP
INLET
Remove the filter from the water inlet

10.3 - REPLACEMENT OF HIGH PRESSURE NOZZLE

Periodically it is necessary to replace the high pressure nozzle as this is a component subject
to normal wear during use. This wear can generally be noticed by a decrease of the working
pressure. Contact your dealer if you wish to purchase a new nozzle.
0,09 liters model IP130
0,14 liters model IP140
0,11 liters model IP150
0,22 liters model IP170
IP170
INLET
IPX
IP150
Clean the filter using an air
pressure gun.
23
IP130-140
Clean the filter under run-
ning water.

Publicité

Table des Matières
loading

Table des Matières