TECHNICAL DATA
Oscillating sander
Production code
Frequency
Power input
Rated input
No-load speed
Orbital travel diameter
Dimensions of grinding plate
Weight according EPTA-Procedure 01/2003
Noise/Vibration Information
Measured values determined according to EN 60 745. Typically, the A-weighted noise levels of the tool are:
Sound pressure level (Uncertainty K=3dB(A))
Sound power level (Uncertainty K=3dB(A))
Wear ear protectors!
GB
DE
Vibration total values (triaxial vector sum) determined according to EN 60745
Vibration emission value a
Uncertainty K=
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745
and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different applications,
with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over
the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is
running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories,
keep the hands warm, organisation of work patterns.
WARNING!
Read all safety warnings and all instructions. Failure to
follow the warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
SANDER SAFETY WARNINGS
Wear ear protectors. Exposure to noise can cause hearing loss.
Appliances used at many different locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Always wear goggles when using the machine. It is recommended
to wear gloves, sturdy non slipping shoes and apron.
Before doing any work on the machine, pull the plug out of the
socket.
Make sure the machine is switched off before plugging in.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
English
Deutsch
8
h
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
The dust produced when using this tool may be harmful to health.
Do not inhale the dust. Use a dust absorption system and wear a
suitable dust protection mask. Remove deposited dust thoroughly,
e.g. with a vacuum cleaner.
Do not machine any materials that present a danger to health (e.g.
asbestos).
This machine is suitable only for dry sanding.
MAINS CONNECTION
Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
SPECIFIED CONDITIONS OF USE
The orbital sander can be used for sanding wood, plastics and
metal.
SPS 140
220-240 V
4470 16 01...
4470 26 01...
... 000001-999999
50/60 Hz
1,2 A
260 W
14 700 min
-1
1,6 mm
113 x 105 mm
1,6 kg
79,5 dB (A)
90,5 dB (A)
8,0 m/s
2
1,5 m/s
2