Commissioning
Requirements:
Screw driver (Phillips)
Connecting cable with at least 2.5 mm
Grommet (ring-shaped cable shoe: insulated or non-insulated)
with an inner ring diameter of 4 mm min. and 6 mm max.
Proper earth connection close to the installation site (equipotential
bonding rail of the house installation or protective earth conductor)
1.
Connect the connecting cable to the potential compensation bar of
the house installation or the protective earth conductor.
2.
Guide the connecting cable to the rear side of the casing.
3.
Join the grommet to the connecting cable and attach it to the earthing terminal.

Opening the Casing

Warning: Improper handling of the device can cause life-threatening electric shocks
and can damage or destroy the PBX.
• Only a qualified electrician may open the casing and perform installation work within
an open casing.
Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
of the power supply unit (for instance ringer voltages). Work on active, contact-
hazardous parts is only permitted after creating a voltage-free state. Working close to
active parts is only permitted if these parts are voltage-free or are protected against
direct contact.
• Disconnect the power plug of the PBX and its accessories before instructing a
qualified electrician to open the casing. Also disconnect the device from additional
power sources (e.g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
Warning: Power surges, which may occur during electrical storms, can cause life-
threatening electric shocks, or damage or destroy the PBX.
• Do not touch the PBX or any devices connected to it during an electrical storm.
Requirements:
Screw driver (Phillips)
1.
Loosen the four screws which hold the front panel.
2.
Lift the front panel off the casing.