Connection AXONIC/CF51-CF55-Pulse-Box
Always make sure that the housing and gasket line up properly.
4.2 - Specification of connection to integrator
Cable A: 4 wires connecting cable, used for connection to integrator
Allocation of wire colors:
1 - WHITE: µCom/diagnostic
2 - BLUE: pulse A or diagnostic
3 - BLACK: earth connection (-)
4 - RED: power supply AXONIC (+)
Cable B: 3 wires connecting cable, used for connection to any devices
Allocation of wire colors:
• RED: Pulse B
• BLACK: earth connection (-)
• WHITE: DIR. (Direction of the flow: 1 = normal flow, 0 = backword flow)
4.3 - Characteristic of pulse outputs (A+B):
• conform to class OB, OC and OD of EN1434-2
• Type:
• Polarity:
• Duration of pulse:
• Max voltage:
• Max current:
• Drop of voltage when switched on:
• Max output frequency:
• Resistance when switched off:
• Pulse length according table
• Max. cable length:
DN65 - qp 25
Pulse Weight
8
p/L
4
p/L
2
p/L
1
L/p
2,5
L/p
10
L/p
100** (200, 500)
25
L/p
100** (200, 500)
100-2500
L/p
100** (200, 500)
8
DN80 - qp 40
5
n.a.
n.a.
5
n.a.
n.a.
20
20
50
50
100** (200)
100** (200, 500)
100** (200, 500)
Connection AXONIC/CF800
Open Drain
non reversible (observe connection diagram)
see table below
30V DC
27 mA
≤ 0.3V at 0.1 mA /≤ 2V at 27 mA
128 Hz
≥ 6MΩ
10 m
DN100 - qp 60
DN125 - qp 100
Pulse Length (ms)
n.a.
n.a.
5
10
20
100
100** (200)
100** (200, 500)
100** (200, 500)
DN150 - qp 150
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
5
5
10
10
50
50
100** (200)
100
100** (200, 500)