Safety Label; Minimum Clearances To Combustibles - GreenSmart Northfield Manuel D'utilisation

Table des Matières

Publicité

38

Safety Label

The safety (listing) label is on the back of the stove. A copy is shown below.
Tested &
Listed By
REPORT #028-S-50d-5
Certified for USA and Canada
Tested to: ANSI Z21.88-2009/CSA 2.33-2009 "Vented Gas Fireplace Heater", CGA 2.17-M91, UL 307b-1995 "Gas Burning Heating
Appliances for Manufactured Homes", and CSA P.4.1-09 Tested method for measuring annual fireplace efficiency.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing, in Canada or with the
Manufactured Home Constructions and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not
applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the
optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently
located, manufactured (mobile) home (USA only) where not prohibited by local codes. See owner's manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions. Use
only approved coaxial direct vent system to vent this appliance to the exterior. See owner's manual for approved brands of venting.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the
owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer,
service agency or the gas supplier.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
CAUTION:
children, clothing, furniture, gasoline and other liquids having flammable vapors away.
Do not operate this appliance with glass removed, cracked or broken. Replacement of
the panel(s) should be done by a licensed or qualified service person.
Stove Top to Sidewall
Stove Top to Backwall
Stove Top to Cornerwall
Glass Front to Unit
Input Rate on "HI" (BTU/Hr)*
Input Rate on "LO" (BTU/Hr)*
Burner Orifice Size - Front
Burner Orifice Size - Rear
This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4500 feet (0-1370m).
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner's manual for information on making these changes.
Electrical Rating: 115v, 1.5 Amps, 60 Hz
Manufacture
Date:
IGN 0847
© Travis Industries
Portland
Oregon USA
Hot while in operation. Do not touch. Severe burns may result. Keep

Minimum Clearances to Combustibles

10" (254 mm)
5" (127 mm)
5" (127 mm)
36" (914 mm)
L.P.
N.G.
22,000
22,000
6,300
6,700
#64
#54
#58
#52
Optional Blower: #99000142
2009
Jan.
Apr.
2010
Feb.
May
2011
Mar.
Jun.
Index
Northfield
Vented Gas
Fireplace Heater
Alcove Min. Height (Floor to Ceiling)
Alcove Max. Depth
Alcove Min. Width
Minimum Inlet Pressure (inches W.C.)
Maximum Inlet Pressure (inches W.C.)
Manifold Pressure on "HI" (inches W.C.)
Manufactured by:
Jul.
Oct.
Aug.
Nov.
Sep.
Dec.
4091120
38-1/8" (968 mm)
24" (610 mm)
28-1/4" (718 mm)
L.P.
N.G.
11"
5.5"
13"
11"
3.5"
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
www.travisproducts.com
100-01239_000
7"