Configurations de Vent arrière avec terminaison horizontale et élévation du
305 mm minimum
Use 6-5/8" (170mm) Diameter Vent
Horizontal sections require a ¼" (6mm) rise every 12" (305mm) of travel.
Maximum of one (1) 45° or 90° horizontal elbow may be used (see illustration).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
positions.
NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary
slightly, especially when the termination is near a demarcation line.
Diffuser set to open (stock) position).
Do not install the intake damper plate or exhaust restrictor extender plates.
12 feet max (3.6m)
10 feet (3m)
5 feet (1.5m)
0 feet
© Travis Industries
Installation
Exhaust Restrictor Position #5
Intake Restrictor Position #6
Exhaust Restrictor Position #4
Intake Restrictor Position #5
Exhaust Restrictor Position #3
Intake Restrictor Position #3
Min. 1' (03m) Vertical Section Required
Horizontal elbows are elbows placed between
two horizontal sections of pipe. One 45° or 90°
horizontal elbow is allowed for this configuration.
(for qualified installers only)
Horizontal Elbow
4091120
12 feet max (3.6m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01239_000