SCOTT HEALTH & SAFETY Proflow Ex Instructions D'utilisation page 32

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
30
10 Protection classes with Proflow Ex (EN 12941 / EN 12942)
Facepiece
Filter
Full face mask
Sari
Promask
PF 10 P
TM3PSL
CF22 A P
TM3A2 PSL
CF22 B P
TM3B2 PSL
CF22 AB P
TM3A1B2 PSL
CF22 ABE P
TM3A1B2E1 PSL
CF32ABEKP
TM3A1B2E2K2PSL
11 Selection of blower-assisted breathing protector equipped with filter
Type of protective device
Power-assisted half mask with particle filter
TM2P
Power-assisted full face mask with particle
filter
TM3P
Power-assisted face shield with particle
filter
TH1P
TH2P
TH3P
Device with combined filter
Power-assisted half mask with gas filter *)
TM2 gas filter class 1, 2 or 3
Power-assisted full face mask with gas filter
*)
TM3 gas filter class 1, 2 or 3
Power-assisted face shield with gas filter *)
TH1 gas filter class 1 or 2
TH2 gas filter class 1 or 2
TH3 gas filter class 1 or 2
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded.
For power-assisted filtering devices with gas filter, concentration must not exceed 0.05 vol.% in gas filter
class 1 and 0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
Half mask
Face shield
HM-AF
Automask
TM2PSL
TH2PSL
TM2A2 PSL
TH2A2 PSL
TM2B2 PSL
TH2B2 PSL
TM2A1B2 PSL
TH2A1B2 PSL
TM2A1B2E1 PSL
TH2A1B2E1 PSL
TM2A1B2E2K2PSL
TH2A1B2E2K2PSL TH3A1B2E2K2PSL
Multiples of
threshold
concentration
100
500
5
20
100
The specified multiples of threshold value for the gas or
particle filters are given separately, but in all cases the lowest
value applies.
100
500
5
20
100
* * * * * * * * * * *
Face shield
Automask &
Litehood
TH3PSL
TH3A2 PSL
TH3B2 PSL
TH3A1B2 PSL
TH3A1B2E1 PSL
Remarks, limitations
"Open" facepieces, such as helmets or
hoods, do not provide sufficient protection
in case of breakdown or inferior output of
the blower. Therefore, devices of class TH1
must never be used against carcinogenic,
very poisonous or radioactive gases and
vapours
For devices with combined filter apply the
relevant limitations of gas and particle
filters.
Hood
Face shield AF
Flow-
hood
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -

Publicité

Table des Matières
loading

Produits Connexes pour SCOTT HEALTH & SAFETY Proflow Ex

Table des Matières