Replacing the battery
1
4
7
10
1
Detach breathing hose.
2
Detach body tensioner.
3
Remove blower from its body by turning it towards yourself with your fingertips (using your
thumb to grip the blower).
4-6
Carefully take hold of the battery leads and pull the battery out of the blower body. Open
the big snap coupling and change the battery. (The rubber band included with the battery
will secure the coupling in the proper position.) Attach the small coupling (=activation of
battery). Reattach the big coupling. Press the battery in to its base.
7
Insert the blower's thread into the body opening and, using your fingers, guide the leads
toward the battery space (the leads must not be left at the air channel in the middle of the
blower body).
8-9
When the blower's thread is slightly visible in the body opening, press the blower into place
with the palm of your hand.Center the blower's thread in the body opening.
10-12 Position the body tensioner. Screw the detached threaded bushing tightly on the blower's
thread to make the body tensioner fit correctly and to make it easy to screw the heads to
each other. Leave a space of 3 - 5 mm between the heads. Make sure that the blower's
thread is properly centered in the body tensioner's opening. Remove the bushing.
13
Charge the battery. When not in use, prevent over-discharge of battery by keeping the
blower device always on recharge.