2.4.9. Checks to electrical devices
Repair and maintenance to electrical components shall include
initial safety checks and component inspection procedures. If a
fault exists that could compromise safety, then no electrical
supply shall be connected to the circuit until it is satisfactorily
dealt with. If the fault cannot be corrected immediately but it is
necessary to continue operation, an adequate temporary solution
shall be used. This shall be reported to the owner of the
equipment so all parties are advised.
Initial safety checks shall include:
• Those capacitors are discharged: this shall be done in a safe
manner to avoid possibility of sparking;
• That there no live electrical components and wiring are exposed
while charging, recovering or purging the system;
• That there is continuity of earth bonding.
3.

Description of the appliance

FIG.1.1: Control panel
FIG.1.2: Top cover
FIG.1.3: Front housing
FIG.1.4: Wheels
FIG.1.5: Cold air outlet/Swing leaf
FIG.1.6: Rear housing
FIG.3: Window kit
FIG.4: Exhaust pipe
Remark : images for illustration, they may differ from your product as
a result of updates.
WARNING!
Install the unit in rooms which exceed 13 m².
Do not install the unit in a place where
inflammable gas may leak.
NOTE!
The manufacture may provide other suitable
example or may provide additional information
about the refrigerant odor.
FIG.2.1: EVA filter
FIG.2.2: Rear panel
FIG.2.3: Exhaust outlet
FIG.2.4: Drain hole
FIG.2.5: Power cord
FIG.2.6: Handle
FIG.2.7: Continuous drain hole
FIG.2.8: CON filter