Siemens SIRIUS 3RW44 2 Série Instructions De Service page 19

Masquer les pouces Voir aussi pour SIRIUS 3RW44 2 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Factory
Customer
Settings
Response to warning
Unchanged
On
Blinking
x
Flickering
Reaction time keys
60 %
Auto repeat
Time
80 ms
Speed
80 %
Activity monitoring time
30 s
Response to ...
Overload - therm. motor model
Tripping without restart
x
Tripping with restart
Warning
Overload - temperature sensor
Tripping without restart
x
Tripping with restart
Warning
Current limit value violation
Warning
x
Tripping
Overload - contact block
Tripping without restart
x
Tripping with restart
Asymmetry
Warning
Tripping
x
Ground fault
Warning
x
Tripping
Name
Name
2)
Fieldbus
Fieldbus interface
Off
x
On
Group diagnosis
Disable
x
Enable
Behavior on CPU/master-stop
Switch substitute value
x
Hold last value
Station address
126
Baud rate
Substitute value
Motor right
Motor left
Slow speed
Emergency start
Output 1
Output 2
Parameter set 1
Parameter set 2
Parameter set 3
Lock quickstop
Parameters disabled CPU/Master
Off
x
On
Saving options
Save settings
Restore settings
Restore basic factory settings
Reset Web login
3ZX1012-0RW44-0AA0
Motor control
ESC
OK
Settings
Motor control via keys
Activate / deactivate key control
Select parameter set
Parameter set 1
Parameter set 2
Parameter set 3
Execute control function
Motor right
1)
Motor left
Slow speed
Emergency start
Output 1
Output 2
Control motor via inputs
Activate / deactivate control via
inputs
Standard control
Automatic / None
Inputs
Keys
1)
Possible only in connection with slow speed
2)
Menu item Settings > Fieldbus from product version
E12 with activated PROFINET communication module
see right menu item
only if Web server is activated
3)
only if NTP time synchronization
4)
is activated
Statistics
ESC
OK
Log lists
Device errors
Trips
Events
Maximum pointer
Currents (%)
Phase current L1 min
Phase current L2 min
Phase current L3 min
Phase current L1 max
Phase current L2 max
Phase current L3 max
2)
Currents (rms)
Phase current L1 min
Phase current L2 min
Phase current L3 min
Phase current L1 max
Phase current L2 max
Phase current L3 max
Phase-to-phase voltages
UL1 - L2 min (rms)
Fieldbus
UL2 - L3 min (rms)
UL3 - L1 min (rms)
UL1 - L2 max (rms)
UL2 - L3 max (rms)
UL3 - L1 max (rms)
Maximum tripping current IA (%)
Maximum tripping current IA (rms)
Number of overload trips
Minimum line frequency
Maximum line frequency
Max. cooling temperature
Max. contact block heating
Reset all maximum pointers
Statistics data
Motor current Imax (%)
Motor current Imax (rms)
Last trigger current IA (%)
Last trigger current IA (rms)
Operating hours - device
Operating hours - motor
No. of starts motor right
No. of starts motor left
Number of overload trips
Number of braking stops
No. of starts output 1
No. of starts output 2
No. of starts output 3
No. of starts output 4
Safety
Factory
Customer
ESC
OK
Settings
Settings
Enter user code
1000
User level
Customer read (> 1000)
Customer write (1000)
Menu item Settings > Fieldbus from pro-
duct version E12 with activated PROFI-
NET communication module
Factory
Customer
Settings
Fieldbus interface
Off
x
On
Group diagnosis
Disable
x
Enable
Behavior on CPU/master-stop
Substitute value
x
Hold last value
Device name
IP address
Subnet mask
Router address
MAC address
Web server
Off
x
On
3)
User name
3)
Old password
3)
New password
OPC-UA server
Off
x
On
OPC-UA server control function
Off
x
On
NTP time synchronization
Off
x
On
4)
NTP server IP address
4)
NTP display offset
Substitute value
Motor right
Motor left
Slow speed
Emergency start
Output 1
Output 2
Parameter set 1
Parameter set 2
Parameter set 3
Lock quickstop
Parameters disabled CPU/Master
Off
x
On
Settings
19