Location Requirements - Jenn-Air LI3W7D Instructions D'installation Et Guide D'utilisation Et D'entretien

Pour îlot de 91,4 cm et 106,7 cm
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For non-vented (recirculating) installations, you will also
need:
Charcoal Filter Kit Part Number W10272068 for non-vented
(recirculating) installations only. See "Assistance or Service"
section to order.
Recirculating Kit Part Number W10272061 for non-vented
(recirculating) installations only. See "Assistance or Service"
section to order.
8" (20.3 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
Filter—installed in hood canopy
4 - 4 x 8 mm screws
5 x 45 mm screws (4)
Mounting template
2 - Upper vent covers
2 - Lower vent covers
Vent transition with backdraft damper installed
2 - 4 x 8 mm mounting screws
4 - Plastic vent clips
Upper horizontal support bracket
Horizontal support
8 - Vertical supports
4 - 3 x 6 mm screws
®
®†
T10
Torx
adapter
T20
®
Torx
®
adapter

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 lbs (36.6 kg).
This range hood is recommended for use with cooktops with
a maximum total rating of 60,000 Btus or less.
The range hood is factory set for venting through the roof.
For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installations" in "Install Range Hood" section.
Recirculation Kit Part Number W10272061 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
†®TORX, T10 and T20 are registered trademarks of Acument Intellectural Properties, LLC.
4
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280) or when such standard is not
applicable, the standard for Manufactured Home Installation 1982
(Manufactured Home Sites, Communities and Setups) ANSI A225.1/
NFPA 501A, or latest edition, or with local codes.
Product Dimensions
12¹⁄₄"
(31.0 cm)
13³⁄₁₆"
(33.5 cm)
42" (106.4 cm)
36" (91.2 cm)
*Vented installations only
**Non-vented (recirculating) installations only
Installation Dimensions
B
D
A. Ceiling height
B. Hood height from ceiling to bottom of the
range hood: A-C-D=B
C. 24" (61.0 cm) minimum to 36" (91.4 cm)
maximum suggested hood height.
D. Countertop height
IMPORTANT:
Minimum distance "C": 24" (61.0 cm) from electric cooking
surface.
Minimum distance "C": 27" (68.6 cm) from gas cooking
surface.
Suggested maximum distance "C": 36" (91.4 cm)
**32¹⁄₂"
*32¹⁄₂"
(82.6 cm)
(82.6 cm)
min.
min.
**52⁹⁄₁₆"
*46¹⁄₂"
(133.5 cm)
(118.0 cm)
max.
max.
27" (68.6 cm)