INSTALLATION SPECIFICATIONS

1-phase
3,7 kW
3-phase***
11 - 22 kW
RCD 1-phase
RCD 3-phase
Power cable above ground
Power cable underground
Cable attachment
Ethernet cable connection
Caution!
The charge point is connected to the electricity grid. Even if the equipment is switched off, hazardous voltages may be
present at the input clamps. Always switch off the AC supply before performing maintenance. The safety guidelines are
intended to ensure correct installation and usage. Any failure to comply with the valid safety guidelines or instructions
provided in this manual may result in fire, electrocution or severe injury.
The charge point is a product in Safety Class I and is supplied with an earth clamp for protection purposes. The AC input
clamps must be fitted with an uninterruptable earth for protection purposes. Ensure that the connection cables are fitted
with fuses and circuit breakers. Never replace a protection component with another type. Consult the manual to deter-
mine the correct component. Before you switch on the charge point, check that the available power source matches the
configuration settings of the product, as described in the manual.
* Always wire for the maximum hardware amperage under continuous load. Cable diameters are an indication,
NewMotion advises to always use one size bigger. The electrician is responsible for selecting a cable thickness
appropriate for your specific situation.
** The charge point can be set between 10 A and 16 / 32 A. The electrician must select an MCB to match the amperage
setting of the charge point.
*** The 3-phase charge point can also be connected to 1-phase. In that case the charge point can only charge on
1-phase.
INSTALLATION INSTRUCTION – ENGLISH – P8
Wiring*
< 50 m
> 50 m
3 x 4 mm
3 x 6 mm
2
2
5 x 6 mm
5 x 10 mm
2
30mA Type B, or 30mA Type A in combination with appropriate equip-
ment that guarantees power shutdown at DC leakage of more than 6mA.
30mA Type B, or 30mA Type A in combination with appropriate equip-
ment that guarantees power shutdown at DC leakage of more than 6mA.
YMvK
YMvK-As
At least PVC tube with clamping brackets and saddles
Standard CAT5 or CAT6 Ethernet cable (UTP cable with RJ45 connector)
Setting
MCB**
16 A
20 A type C
16 A
20 A type C
2
20 A
25 A type C
32 A
40 A type C