Safety features
In case of internal overheating, the overheating safeguard will switch the heater off. This may occur if the
heater cannot give off enough heat or cannot draw in enough fresh air. As mentioned above, this is generally
caused by (partially) covering the heater, obstructing the air intake and/or outlet grills or installing the heater too
close to a wall or something similar. In case of overheating, turn off the heater, unplug and allow the heater to
cool down. Once the reason for the overheating has been removed or amended, you can use the heater again as
usual. If the cause of overheating is unclear and/or overheating occurs regularly, stop using the appliance and
take it to a qualified professional for repair and/or inspection.
Once the heater has been turned off and allowed to cool down after overheating, it will resume its function
automatically. This does not mean, however, that the cause of overheating has been rectified. If the heater
repeatedly switches on and off due to overheating, this may pose a fire risk so make sure this does not occur!
Cleaning and Maintenance
Keep the heater clean. Deposits of dust and dirt in the appliance are a common cause of overheating and should,
therefore, be regularly removed. Before carrying out cleaning or maintenance work, switch the heater off, remove
the plug from the socket and allow the heater to cool.
Wipe the outside of the heater regularly with a dry or slightly damp cloth. Do not use aggressive soaps,
sprays, cleaners or abrasives, waxes, polishes or chemical solutions!
Using a vacuum cleaner, carefully remove any dust and dirt from the grills and ensure that the air intake
and outlet openings are clean. Be careful not to touch or damage any internal parts during cleaning!
The heater contains no other parts which need maintenance.
At the end of the season, store the cleaned heater in the original packaging if possible. Store upright in a
cool, dry and dust-free place.
Do not dispose of heater with household waste when it becomes worn or damaged beyond repair. Take
it to your local authority's collection point for electrical appliances where any reusable materials will be
collected and redistributed.

Problems and Solutions

If the heater does not work even though it is plugged into the socket, check the following:
- Is the plug properly inserted and is the socket live? Replace the fuse, if necessary.
- Is the thermostat set too high? If so, turn it down slightly.
- Did the overheating safeguard switch the heater off? See Safety Features for course of action.
For any other problems, please contact a qualified electrician. Never open the heater yourself!
CE-statement
Euromac bv, Genemuiden-NL hereby declares that the EUROCOM frost shield CK401IP complies with the
LVD-guideline 2006/95/EC and the EMC-guideline 2004/108/EC and that it meets the following standards:
EN 60335-1:2002+A11,A1 :04+A12,A2 :06
+A13 :08+A14 :10+A15 :11
EN 60335-2-30:2003+A1:04+A2 :07
EN 62233:2008
Genemuiden, 16-09-2013
-----------------------------------------------------------------------------------------------------------------
Données techniques
Type
Tension
Puissance max.
Thermostat
Classe de protection
Dimensions
Poids
W.J. Bakker, alg.dir.
Français
:
CK401IP
:
220-240 Volts
:
400 Watts
:
réglable
IP24 (protection contre les projections d'eau)
:
:
10,2 x 29,5 x 25 cm
:
1,0 kg
EN 55014-1:2006/+A1 :2009/+A2 :2011
EN 55014-2:1997/+A1 :2001/+A2 :2008
EN 61000-3-2:2006/+A1 :2009/+A2 :2009
EN 61000-3-3:2008