Location And Connection; Set-Up And Operation - EUROMAC EUROM CK401IP Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Not abiding by instructions 23, 24 and 25 may lead to damage, fire and/or personal injuries. A failure to ahdere to
these rules also immediately nullifies the guarantee and the vendor, importer and/or manufacturer take no
responsibility for any of the consequences!
Description

Location and Connection

Remove all packaging material and keep out of reach of children. After removing packaging, check the
appliance for damage or other signs that could indicate a fault/defect/malfunction. In case of doubt, do not
use the appliance, but contact your vendor for inspection or replacement.
Choose a suitable location for the heater, i.e. at least one metre away from any obstructions, walls or
inflammable materials (see also safety instructions).
The heater needs to be mounted on the wall. Make sure the wall is solid, totally vertical and non-flammable.
Do not use wooden or synthetic walls! The distance between the bottom of the heater and the floor should
be at least 20 cm. The distance between the heater and the sidewalls should be at least 30 cm and the
distance between heater and ceiling at least 50 cm. Do not mount the appliance directly below or in front of
a socket.
bracket. Make sure the heater and bracket are securely attached and that the heater is
completely horizontal.
If desired, the CK401IP can be permanently connected to the power supply by means
of a suitable junction box (not included). This procedure needs to be performed by a
professional! A disconnection device at a minimum distance of 3mm (e.g. an automatic
power switch, an on/off switch) must be provided for heaters which are permanently
connected to the power supply in order that they may be switched off.

Set-up and Operation

The frost shield is now ready to use. Insert the plug into a suitable 220-240V-50Hz grounded socket to
switch on the heater. Only connect the heater to an earthed socket!
To set the desired temperature, turn the thermostat dial to maximum (biggest dot, or clockwise as far as it
goes). Wait for the desired temperature to be reached and then slowly turn the knob until the pilot light goes
off. The desired temperature is now set; when the temperature in the immediate vicinity drops to under this
level the heater will switch on, as will the light. To set the temperature to a higher or lower level, turn the
thermostat dial to either 'maximum' (biggest dot) or 'minimum' (star).
Turning the thermostat dial to 'minimum' (star) means that the frost shield will keep the area frost-free (as
long as the area is not too big or too cold).
The appliance will function even when set to the lowest level. To fully switch off the heater, you must remove
the plug from the socket (or, in case a switch has been installed, by switching this to 'off').
The CK401IP frost shield is an electrical convector heater
with a thermostat and an overheating safeguard. The light is
illuminated when the frost shield is switched on. The
CK401IP frost shield is intended to keep small domestic or
similar spaces frost-free. The heater may only be used when
mounted on the wall (never if it is standing up or lying down!)
and only for the purpose for which it was designed.
1 = air outlet grill
2 = pilot lamp
3 = thermostat dial
4 = air inlet grills
Loosen both screws on the
suspension bracket and fix the
assembly bracket horizontally to
the wall, using the screws
provided. Slide the heater back
over the bracket and secure
both screws at the side of the
11

Publicité

Table des Matières
loading

Table des Matières