L14<
3 Quick reference instructions
3.1 Selection of the operating mode
Select the desired operating mode by repeatedly pressing the MODE button until the correct text is displayed. The operating mode will
change 10 seconds after altering the setting (symbol changes on the display).
Cooling
Summer
Auto
Vacation
Party
2nd heat generator
3.2 Changing the settings
Press and hold the MENU button for several seconds
Select the desired menu item with the arrow buttons (
)
Confirm by pressing the ENTER button (
Select the desired submenu item with the arrow buttons (
and
)
3.3 Settings and operating data
Menu for setting system-specific parameters (see Chapt. 8 on
pp. 7). Dynamic menus hide non-essential settings.
Time
Mode
Heating circuit 1 Settings for heating circuit 1
Heating circuit 2 Settings for heating circuit 2
Heating circuit 3 Settings for heating circuit 3
Cooling
Domestic
water
Swimming pool
Date
Language
Downloaded from
www.Manualslib.com
The system operates in cooling operation.
Domestic hot water heating and swimming pool water heating only. Frost protection is ensured.
Programmed raising and lowering times are automatically activated.
The temperature is lowered and the domestic hot water is blocked for an adjustable time period.
The programmed lowering of the heating characteristic curves is overridden.
Heat pump is blocked. Heat is generated by the 2nd heat generator.
)
Sets the time and activates automatic
operating mode switching from summer to
winter.
Various operating mode settings available
(see Chapt. 3.2 on pp. 3)
Settings for cooling operation
hot
Settings
for
domestic
preparation
Settings for swimming pool heating
Sets the date
(required for leap years only)
Sets the language
for menu navigation
manuals search engine
Confirm with the ENTER button (
the setting
and
Change the setting to the desired value with the arrow
buttons (
Confirm the new value with the ENTER button (
changes with the ESC button
Heating characteristic curve (see Chapt. 6 on pp.
6)
The heating characteristic curve can be adjusted to individual
temperature requirements using the hotter/colder buttons on the
main display. Increase or reduce the temperature with the
buttons. For heating circuit 2/3, make this setting in the menu
"Heating circuit 2/Heating circuit 3".
Domestic hot water heating (see Chapt. 7 on pp. 6)
The domestic hot water temperature and a shut-off time for
domestic hot water heating can be set in the menu item "Settings
– Domestic hot water". This can be used to change the time for
domestic hot water preparation, for example at night. An option is
also available for time-controlled reheating of domestic hot water
using a flange heater.
hot
water
Operating data menu (see Chapt. on pp. 9)
Displays the measured sensor values.
History menu (see Chapt. 8.4 on pp. 14)
Displays runtimes and stored data (e.g. faults).
Displays (see Chapt. 9 on pp. 17)
Display the current operating status of the heat pump
system
Alarm messages: (ESC button flashes)
452114.66.71 FD 9305
Wärmepumpenmanager
) until the cursor jumps to
and
)
) or discard
/
EN-3