KitchenAid KBFN536TPA Guide D'utilisation page 19

Table des Matières
Les langues disponibles

Les langues disponibles

Contaminant Reduction
Metolachlor
TCEP
TCPP
Phenytoin
Ibuprofen
Naproxen
Bisphenol A
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 GPM (1.89 LPM). Pressure = 60 psi (413.7 kPa).
Temperature = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants."
Emerging compounds/incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels.
While occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality.
� For installation, operation, and maintenance instructions please
refer to the Owner's Manual.
� It is important that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised. Property damage can occur if all
instructions are not followed.
� The disposable cartridge must be changed at least every
6 months.
� Use replacement filter part #EDR3RXD1/EDR3RXD1B. 2025
suggested retail price of $59.99 U.S.A./$69.99 Canada. Prices
are subject to change without notice.
� The filter monitor system measures the amount of water that
passes through the filter and alerts you when it is time to replace
the filter. To learn how to check the water filter status, see "Using
the Controls" section page 8 or "Water Filtration System" section
page 11 in the Owner's Manual.
� After changing the water filter, flush the water system. See
"Water System Preparation" section page 6 in the Owner's
Manual.
� These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
Consumer Support 1.800.442.9991
By Whirlpool Corporation
2000 North M63
Benton Harbor, MI 49022
Made in Taiwan.
*Class I particle size: > 0.5 um to 1 um
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
††
®
NSF is a registered trademark of NSF International.
Influent Challenge
Concentration
1400 ng/L ± 20%
5000 ng/L ± 20%
5000 ng/L ± 20%
200 ng/L ± 20%
400 ng/L ± 20%
140 ng/L ± 20%
2000 ng/L ± 20%
Maximum Permissible
Product Water Concentration
200 ng/L
700 ng/L
700 ng/L
30 ng/L
60 ng/L
20 ng/L
300 ng/L
� The product is for cold water use only.
� The water system must be installed in compliance with state
and local laws and regulations.
� Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
EPA Est. No. 082047-TWN-001.
� Refer to the "Warranty" section for the Manufacturer's limited
warranty, name and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
� Your water filtration system will withstand up to 120 pounds per
square inch (psi) water pressure. If your water supply is higher
than 80 psi, install a pressure reducing valve before installing
the water filtration system.
Average % Reduction
> 98.7%
> 98.0%
> 98.0%
> 93.8%
> 93.9%
> 95.8%
> 98.9%
Potable City or Well
30 psi-120 psi
(207 kPa-827 kPa)
33°F-100°F (0.6°C-37.8°C)
0.5 GPM (1.89 LPM)
@ 60 psi (413.7 kPa)
19
Table des Matières
loading

Ce manuel est également adapté pour:

Kbfn542tpa

Table des Matières