Operating Instructions
TWILIGHT CONTROL
The critical value is pre-set to --.
The twilight function is not activated if the setting is --.
The brightness settings range from 01 (night) to 15 (early twilight).
The display shows the current twilight setting and the new setting to be made. The new
setting to be made flashes.
TEST Mode
(To activate the test mode, a complete UP command must be executed)
The SC43 can be tested in this mode. When the test mode has been activated, the word
TEST will appear on the display.
In the TEST mode, the sunshade function times are shortened.

Assembly/Connection

Assembling SC43 to the time switch for light sensors Centronic TimeControl
TC52 / radio-operated time switch for light sensors Centronic TimeControl
TC511
Connection to device
1. Cut the wire to the desired length (e.g. using a diagonal cutter).
2. Bare about 5cm of the wire.
3. Insert the wire into the terminal.
4. Insert the terminal into the receptacle (see diagram).
Window assembly for SC43:
Attach the SC43 to the window using the suction cap.