Switch Off - Warm Tech Wtcacg18V-920 Traduction Des Instructions D'origine

Appareil de chauffage au gaz avec ventilateur
Table des Matières
Les langues disponibles

Les langues disponibles

3.1 IGNITION / Manual ignition
a. Turn the power switch to position ON and check that the fan starts running correctly. (Fig
4.)
b. Push the gas valve button and push repeatedly the piezoelectric lighter until the flame lights
up. (Figure. 5-6-7)
Figure.5
c. As the flame lights up, keep the valve button pushed for 10 seconds approx. Should the
heater stop when the valve button has been released, wait one minute and repeat the
starting operation keeping the valve button pushed for a longer time.
d. Regulate the gas flow pressure according to the thermal power desired, by turning the
wheel of the pressure reducer anticlockwise to increase the pressure or clockwise to
decrease.
e. Contact your supplier should any problem continue.
CAUTION
If ignition is difficult or irregular before repeating the ignition operations make sure
that the fan is not locked and the air inlet and outlet are unobstructed.

3.2 SWITCH OFF

To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts down
and then turn the fan switch to position OFF
XPCACG20LI
Figure.6
(Fig 3.)
Figure.4
Figure.7
Table des Matières
loading

Table des Matières