Les langues disponibles

5. Locate thick rubber gasket on mounting surface and set housing on top of gasket.
Secure to mounting surface using the appropriate user supplied #6 (3.5mm) screws.
6. Refer to section C for information on making electrical connections.
b. Surface Mounting using LP3T.
1. Using gasket as a template, or the dimensions shown in figure 3, mark two mounting
holes and center wiring hole (if wiring is to enter through bottom of unit). Drill or
punch out holes as necessary.
2. Locate rubber gasket on mounting surface and set housing on top of gasket. Secure to
mounting surface using the appropriate user supplied # 10 (5 mm) screws.
3. Refer to section C for information on making electrical connections.
B. Specifications.
Operating Voltage
Operating Current
Energy Output
Flash Rate
Operating Temperature
Approvals
Additional Approvals
Environmental Ratings
C. Electrical Connections.
The Model LP3 comes assembled from the factory. Two 9" long lead wires are supplied on the
12-48 volt DC model of LP3T. All other models are supplied with a two position terminal
block for making wiring connections.
1. Terminal Block Wiring.
If the strobe light has not been disassembled previously for mounting, perform the
following steps:
a. Remove lens from housing by turning counter-clockwise.
b. Remove printed circuit board assembly by depressing the two snap tabs inside the
housing and lift the board assembly upwards.
c. If supply wires were not previously drawn into housing previously, feed supply wires (14
to 18 AWG only) through large hole in bottom of housing.
d. Strip a maximum of 0.25" (6.4mm) of wire insulation from the ends of the power leads.
Connect wires to terminal block by inserting the stripped ends of the wire into connector
as far as they can travel and tightening clamping screw.
Be sure to observe polarity on the 12-48 VDC printed circuit board assembly. The terminals are
designated by a "+" and "-" on the terminal block for the positive and negative
The maximum tightening torque is 5 in-lbs (.056 N-m) for field wiring connections on
the terminal block. Make sure power supply lead insulation is flush with connector. If
stranded wire is used, be sure that there are no loose strands outside the connector that
could touch the adjacent lead to cause a short circuit.
12-48VDC
120VAC 50/60 Hz
.44 - .10A
2.0 Joules
65-95 FPM
-31°F to 150°F (-35°C to 66°C)
UL, cUL (excluding LP3T 12-48VDC)
CE (excluding LP3E, LP3T, and all 120/240VAC models)
Indoor/Outdoor Use, Type 4X, IP66 (LP3T, IP55)
NOTE
supply leads, respectively.
-2-
230-240VAC 50/60 Hz
.10A
2.0 Joules
65-95 FPM
.07A
2.0 Joules
65-95 FPM