B E R O T E C
E x p e r t m o d e
The expert mode is a possibility integrated in the chain oiler to freely adjust the lubrica-
tion quantity independent of the steps 0-9.
The levels 0-9 set the time between the lubrication intervals. These are permanently sto-
red, tried and tested and sufficient for most applications:
Level
0
1
2
3
4
5
6
7
8
9
If a stronger or weaker lubrication is desired, a free time interval can be set:
Set rotary switch to level 0
»
Level 0 is used as a memory location for the freely programmed time. The table value
»
(445 seconds) is finally overwritten.
Press and hold the rain switch for 10 seconds (ignoring that the rinse mode is activa-
»
ted after 4 seconds, keep the switch pressed)
After 10 seconds the LED starts flashing every second, the switch can now be relea-
»
sed.
Stop time or count seconds (flashing) until the desired setting is reached.
»
Press
the
»
hing,
time
The setting range is limited between 10 seconds and 3600 seconds (1 hour).
The procedure can be repeated as often as required, the old setting is overwritten.
»
The lubricant quantity for the rain mode is automatically adjusted to ten times the
»
amount.
Levels 1-9 can be used unchanged.
»
20
Time interval [sec]
rain
switch
has
been
saved
MOFESSOR
445
406
367
329
290
251
213
174
135
96
again
in
the
controller
English
Time interval [sec]
Rain Mode
45
40
37
33
29
25
21
17
13
9
LED
stops
to
level
flas-
0.