GFS model includes a Failsafe unit and a GF3 (3-position unit).
Power supply
N / -
Ph / +
O
1
2
TP/PE
100 V-240 V 50/60 Hz (100 V-350 V DC)
15 V-30 V 50/60 Hz (24 V-48 V DC)
M
B
Rep.
Designation
FC0
Open limit switch
FCF
Close limit switch
FCIO
Intermediate open limit switch
FCIF
Intermediate close limit switch

The terminal temperature can reach 90°C

The used wires must be rigid (feedback voltages : 4 to 250V AC/DC)

For a use with a long power supply wiring, the induction current generated by the wires mustn't be higher than 1mA.
46
A
0
B
F
I
3
4
65
66
D3
D4
17
17
18
18
A
A
~
+
~
Battery block
F+
F-
T+
red
Black/white
white
F+
F-
T+
Attery charged
contact closed
F6 F7 F8
A
B
C
F6
F7
F8
Rep.
Designation
FC1
Auxiliary limit switch 1
FC2
Auxiliary limit switch 2
FC3
Auxiliary limit switch 3
D3/D4
Failure report Terminal strip (24V DC / 3A max)
EN
Feedback
4
8
6
9
SNAA710000
DSBA3400 • Rév. 30/01/2020
F4
F9