Elica EMD530S3 Guide D'utilisation, D'entretien Et D'installation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

C
B
A. Rear vent knockout
B. Rear rectangular transition knockout mounting screws (3)
C. Rear rectangular vent transition
9 Remove one of the round knockout from the top or back
of the range hood (depending on your wiring location)
for the wiring strain relief and install a
approved strain relief.
A. Round knockout
Top vent transition installation
1
Remove the top vent knockout.
2 Attach the round vent transition damper using 2-3.5 x 9.5 mm
vent transition mounting screws.
3 Remove tape from damper flap.
B
A
A. Top round vent transition
B. Top round vent transition mounting screws (2)
C. Top vent knockout
For non-vented (recirculating) installations
1
Remove the blower mounting screws. Push up on the
blower to detach the blower from the mounting plate.
A
B
2 Rotate the blower and attach to front mounting plate.
Install the blower mounting screws
A
B
3 Install charcoal filters. See the "Maintenance" section.
A
" UL listed or CSA
1
2
A
C
A. Front mounting plate knockout
B. Blower
A. Front mounting plate
B. Blower
Install range hood to cabinet
1
Using 2 people, lift range hood into final location. Feed
enough electrical wire through the strain relief to make
connections in the terminal box. Tighten the strain relief
screws.
2 Position the range hood so that the large end of the
keyhole slots are over the mounting screws. Then push the
hood toward the wall so that the screws are in the neck of
the slots. The hood should be against the wall. Tighten the
mounting screws, making sure mounting screws are in the
narrow neck of the slots.
A
A. 4- mounting screws
3 Check that damper, if used, rotates up and down freely.
4 Connect ventwork to hood. Seal joints with clamps to
make secure and airtight.
Install range hood to the wall
1
Fix the wiring conduit of the hood.
2 Slide the hood back against the wall. Tighten the mounting
screws. Be sure the screw heads are in the narrow neck of
the keyhole slot.
A
B
D
B
C
3 Insert 2 screws into the upper security screw locations
(see B in the image above). Tighten the screws.
4 Insert 2 screws into the lower security screw location (see
C in the image above). Tighten the screws.
5 5. Connect the Ductwork to the hood.
C
B
B. Security screws
C. Washers
A. Mounting screws
B. Upper security screws
(Wall Installation)
C. Lower security screws
(Wall Installation)
D. Washers
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Emd536s3