Note: See Figures on previous page.
1. Ensure Proper Intake Ventilation. Always ensure
there is proper attic intake ventilation at or near
the soffit area of the roof. This is required for a
balanced ventilation system and to help avoid
premature ventilator motor failure. Use the chart
located on the outside of the package or visit
gaf.com/ventcalculator to ensure the minimum
recommended intake ventilation is installed on
the home. Always consult local building codes for
ventilation requirements.
2. Determine Position. Place vent behind an
existing gable wall louver or install a Master Flow
SGM20 Automatic Gable Louver (not included).
The fan should be approximately 3" (76 mm) to
4" (102 mm) away from the exterior louver.
3. Attach Mounting Brackets to Unit. Carefully
remove unit and mounting accessories kit from
the car ton. The fan mounting kit includes (8)
bolts, (8) Nylok nuts, and (4) mounting brackets.
Take the mounting brackets (long side) and align
with the two holes on the shroud. With holes
aligned, take two bolts with the head on the
inside of the shroud and push through each
hole. Take the Nylok nuts and fasten to each
bolt. Repeat this process until all four mounting
brack ets are firmly fastened to shroud (Figures
1a & 1b).
4. Mount the Unit. Place mounting brackets so end
is flush with the stud. For studs 16" (406 mm) on
cen ter, mounting brackets are predrilled to this
size. Screw or nail unit to framing through pre-
punched holes in mounting brackets (Figure 2a).
For studs over 16" (406 mm) on center, install
two nominal 2" x 4" (50 mm x 100 mm) wood
supports, 14" (356 mm) apart. Mount the unit to
the two nominal 2" x 4" (50 mm x 100 mm) wood
supports through the pre-punched holes in the
mounting brackets (Figure 2b).
gaf.com
5. Wiring. Always disconnect power supply before
wiring the ventilator into an existing circuit.
Remove the cover on the QuickConnect
Controller and mount the metal enclosure on a
rafter or stud utilizing the pre-punched holes in
the orientation as shown in (Figure 3). Ensure
that the TOP on the QuickConnect
label points towards the roof. Each ventilator must
have its own QuickConnect
flexible conduit with some slack and begin wiring
the QuickConnect
Controller as shown in (Figure
3). Note: The included QuickConnect
arrives with factory default settings of temperature
at 105°F and humidity at 70%. These default
settings can be adjusted once the unit has been
wired and you have downloaded the app and
accepted the end user agreement.
Note: In the unlikely event that accessories
or parts are missing, or this product does not
operate correctly, please contact Master Flow
Technical Services at l -800-211-9612 or email
MasterFlowTech@gaf.com. Do NOT return this
ventilator to retailers or distributors.
Featuring:
Master Flow
QuickConnect
Wi-Fi Technology
INSTRUCTIONS
For Gable Mount Model:
EGV5QCT
Figure 3
Controller
Controller. Leave the
Controller
WARNING – Do NOT install QuickConnect
Controller with openings facing down