General warnings
• If the appliance is set up in a suspended ceiling or attic, or above living space, a drain pan
must be installed underneath the water heater. A drainage device connected to the sewer
system is required.
• This product is intended for use at a maximum altitude of 2000 m.
• This water heater is fitted with a thermostat with an operating temperature of more than 60
°C at its maximum position, capable of reducing the growth of legionella bacteria in the tank.
Caution! Above 50 °C, water could cause immediate burns. Check
the water temperature before taking a bath or shower.
HYDRAULIC CONNECTION
• A new safety device which conforms to current standards (EN 1487 in Europe), pressure
0.8 MPa (8 bar) and size 1/2» in diameter must be fitted. The safety valve must be protected
from frost.
• The pressure relief valve drainage device must be activated on a regular basis in order to
remove limescale deposits and to check that it is not blocked.
• A pressure reducer (not supplied) is required if the supply pressure is greater than 0.5 MPa
(5 bar) and will be installed on the main supply pipe.
• Connect the safety unit to a discharge pipe, kept in the open air, in a frost-free environment,
continuously sloping downwards to drain off the heat-expanded water or to allow for drainage
of the water heater.
• DRAIN: Turn off the power and cold water supply, open the hot water taps then operate the
drainage valve of the safety device.
3