Operation, cont'd.
Empty Gray Water Tank(s)
Refer to Fig. 1 and Fig. 5.
1. Make sure universal nozzle (
dump station! Refer to "Attach Pump to RV" procedure.
TIP For Cleaner Storage: Emptying black water tank fi rst,
NOTICE
allows gray water to cleanse the system.
2. Open gray water tank gate valve (
3. Turn pump on.
4. Do not leave unit unattended.
5. Turn pump off.
TIP: The hose expands as fl uid moves to dump station
NOTICE
and contracts when tank is empty.
6. Close gray water tank gate valve
7. Repeat Steps 2-6 for secondary gray tanks.
Gray water bypass is possible if the discharge plumbing
NOTICE
does not fl ow upward.
Prepare Hose For Storage
Refer to Fig. 1 and Fig. 5.
1. Make sure pump is off.
2. Drain hose (
) by holding at a sloped angle to direct excess
K2
water into the dump station.
TIP For Faster Draining: Leave gray gate valve
NOTICE
open allowing hose to vent and expediting the process.
3. Disconnect nozzle (
K2
4. Install cap(s) (
K2.3, K2.4
5. Unhook pump
from power source; remove pump
(K1)
from RV.
6. Install bayonet cap (
K6
7. Return hose and pump to storage box (
connected to pump.
97571 Rev. C (07/10/2017)
) is securely attached to
K2
5B
).
(5B)
.
) from dump station.
).
) on pump
(K1).
); leave hose (
K7
Helpful Hints
Additional hoses can be purchased from Thetford and used
to extend the length of the discharge hose. Connect the
hoses using 1.5" (3.8 cm) barbed coupling with clamp.
If you wish to extend the discharge hose, connect a .75
in (1.9 cm) inner diameter garden hose to the end of the
nozzle.
NOTICE
Before storing the hose, make sure that all liquid has
drained from the hose.
NOTICE
Obstruction Removal
Refer to Fig. 1 and Fig. 5.
NOTICE
1. Make sure all contents have been drained from system.
!
!
!
!
NOTICE
AVISO
ATTENTION
ATENCIÓN
DANGER
CAUTION
AVIS
ATTENTION
ATTENTION
ATTENTION
2. Disconnect pump (
pump fuse or disconnecting the battery.
(5B)
3. Make sure all gate valves (
4. Remove pump (
5. Remove obstruction from pump (
AVISO
!
!
!
!
NOTICE
ATTENTION
DANGER
ATENCIÓN
CAUTION
AVIS
(K1)
ATTENTION
ATTENTION
ATTENTION
6. Attach pump to RV's drain outlet (
7. Reconnect the power.
)
K2
8. Operate system using gray water; check for leaks.
8
A longer discharge hose reduces fl ow rate.
Gray water bypass is possible if the discharge plumbing
does not fl ow upward.
Be sure to have container available for capturing system
fl uid!
Turn off power and remove pump fuse. Once the obstruc-
tion is removed, there is potential injury to hands or
fi ngers in the path of the impeller if the power is on!
) from power (
by removing the
K1
4A)
5B
) are closed.
K1
) from RV's drain outlet (
).
K1
Do NOT remove pump housing. Obstruction MUST be
removed through inlet.
5B
).