Commutateur manuel pour l'alimentation en
courant de secours, isolation tétrapolaire (par ex.
Allemagne)
BESTEHENDE HAUSINSTALLATION
EXISTING DOMESTIC INSTALLATION
L1
L2
L3
N
POTENTIALAUSGLEICHSSCHIENE
MEN - LINK
*1)
kWh
3AC
*2)
=P1
Fronius Smart Meter
-Q1
*8)
Fronius
Backup Switch
Netz - O - Notstrom
Grid - O - Backup
1
3
5
7
I >
2
4
6
8
LAST
NOTSTROMVERSORGUNG
LOAD
DC= IN
PV-GENERATOR
-F3
N
L1
L2
L3
L1
L2
L3
N
T1
T2
T3
T1
T2
T3
1
3
5
7
I >
2
4
6
8
BACKUP LOAD
& BATTERY
=A1
SYMO GEN24
V+
GND
IN6/IN7
CAT5 STP
M+
M-
WSD IN+
WSD IN-
=A1+A2 PILOT / PILOT2
*2)
*7)
WIRED SHUT
DOWN (WSD)
ANSCHLUSS FÜR VON FRONIUS
FREIGEGEBENEN BATTERIEN
(SIEHE BATTERIE-SCHALTPLAN)
CONNECT TO FRONIUS
APPROVED BATTERIES
(REFER TO BATTERY SCHEMATIC)
DER WECHSELRICHTER ERFÜLLT DIE ANFORDERUNGEN
DER "AUTOMATISCHEN ABSCHALTUNG DER
STROMVERSORGUNG IM FEHLERFALL" DURCH
INTERNE ÜBERWACHUNG.
GÜLTIG FÜR SOFTWARE VERSION 1.25.2 ODER HÖHER.
WECHSELRICHTER MIT ÄLTERER SOFTWARE
BENÖTIGEN EIN UPDATE.
THE INVERTER MEETS THE REQUIREMENT OF "AUTOMATIC
SHUTDOWN OF THE POWER SUPPLY IN THE EVENT OF
A FAULT" THROUGH INTERNAL MONITORING.
VALID FOR SOFTWARE VERSION 1.25.2 OR HIGHER.
INVERTERS WITH A SOFTWARE BELOW 1.25.2 NEED AN
UPDATE.
SYMBOL DEFINITION:
VERDRILLTE LEITUNG
TWISTED PAIR
*1)
PE - N VERBINDUNG NUR IM TN-SYSTEM
PE - N CONNECTION ONLY IN TN-NETWORK
DER MODBUS-KOMMUNIKATIONS-BUS ERFORDERT DEN ABSCHLUSS
*2)
DER LEITUNGSENDEN MITTELS ABSCHLUSSWIDERSTÄNDE.
DETAILS SIEHE WECHSELRICHTER-DOKUMENTATION.
THE MODBUS COMMUNICATION BUS REQUIRES THE
TERMINATION OF CABLE ENDS WITH TERMINATION
RESISTORS. DETAILS ACCORDING INVERTER MANUAL.
*7)
IST DER WSD-ANSCHLUSS DES WECHSELRICHTERS
BEREITS BELEGT (Z.B. VON EINEM SPD-PRINT), SIND DIE
KONTAKTE IN SERIE ZU VERDRAHTEN
IF THE WSD-CONNECTION OF THE INVERTER IS
ALREADY USED (E.G. BY A SPD-BOARD), THE CONTACTS MUST
BE WIRED IN SERIES
*8)
AUX.
AUX.
POS.
SWITCH 1
SWITCH 2
closed
open
O
open
open
open
closed
ModBus 0
( PILOT2
4,071,817
ONLY )
237