Safety, Operation

WARNING: ALWAYS use safety gloves
as the edges of cut pipes are sharp and
can cause cuts.
WARNING: Some dust created by power
sanding, sawing, grinding, drilling, and
other construction activities contains chemicals
known to cause cancer, birth defects or other
reproductive harm. Some examples of these
chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement and other
masonry products, and
• arsenic and chromium from chemically-treated
lumber (CCA).
Your risk from these exposures varies, depending
on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are
specially designed to filter out microscopic particles.
Avoid prolonged contact with dust from power
sanding, sawing, grinding, drilling, and other
construction activities.
Wear protective clothing and wash exposed
areas with soap and water. Allowing dust to get
into your mouth, eyes, or lay on the skin may
promote absorption of harmful chemicals.
WARNING: Use of this tool can generate
and/or disbursedust, which may cause
serious and permanent respiratory or
other injury. Always use NIOSH/OSHA approved
respiratory protection appropriate for the dust
exposure.
Direct particles away from face and body.
Extension cords
An extension cord must have adequate wire
size (AWG or American Wire Gauge) for safety.
The smaller the gauge number of the wire, the
greater the capacity of the cable, that is 16 gauge
has more capacity than 18 gauge. An undersized
cord will cause a drop in line voltage resulting in
loss of power and overheating. When using more
than one extension to make up the total length, be
sure each individual extension contains at least the
minimum wire size. The following table shows the
correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next
heavier gauge. The smaller the gauge number, the
heavier the cord.(see page 4).
Motor
Be sure your power supply agrees with nameplate
marking. As little as 10% lower voltage can cause
loss of power and can result in overheating. All
Exact Tools products are factory-tested; if this tool
does not operate, check the power supply.
WARNING: Accessories must be rated
for at least the speed recommended on
the tool warning label. Accessories
running over rated speed can fly apart and cause
injury. Accessory ratings must always be above
tool speed as shown on tool nameplate.
DANGER: Avoid contact with the blade
teeth to prevent personal injury.
NOTE: When using a generator as power
source it has to be TRUE SINE WAVE
style INVERTER GENERATOR with
minimum power of 2000W / 2.5 kVA.

Functional Description

Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Intended Use

PipeCut V1000:
The Exact Pipe Cut V1000 is intended for
professional use at any kind of construction sites.
The Exact Pipe Cut V1000 is designed to be used
only for thin walled ventilation ducts with a diameter
of 3' (75 mm) - 40' (1000 mm).The maximum wall
thickness that the Exact Pipe Cut V1000 can cut
through is 0,08'' (2 mm). With a spiral ventilation
duct the maximum thickness of the seam that the
Exact Pipe Cut V1000 can cut through is 0,24'' (6
mm.) With the Exact PipeCut V1000 you can cut
ducts made from the following materials:
galvanised steel, stainless steel, aluminium and all
kinds of plastic PipeCut V1000 pipe saw is intended
for short, intermittent use. The machine may be
loaded for 2,5 minutes during a 10-minute period
(S3 25 %). PipeCut V1000 pipe saw is not intended
for use in industrial production.

Product Features

While reading the operating instructions, unfold the
graphics page for the machine and leave it open.
This page is folded under the cover of this manual
(page 3). The following numbering of the product
features refers to this illustration.
Figure A
1.
UNLOCK button
2.
Power switch
3.
Power switch locking lever
4.
Motor unit
5.
Blade guard cover
6.
Straight adjustment screw
7.
Edge of moving blade guard
8.
Sight
9.
Operating handle
10.
Blade guard screw
11.
Spindle lock button
12.
Allen key
13.
Rating plate
14.
Overload protection
15.
Manufacturing date (mmyy)
16.
Straight adjustment screw inicator
17.
Steering unit
18.
Safe for the steering unit
19.
Steering unit indicator
20.
The knob for the steering unit