Switch Check Flow-Chart
FAULT:
Motor runs but switch will not latch.
QUESTION: Did the machine
stop whilst running?
YES
ACTION: Check and test the thermal
protection device.
METHOD: Switch off the mixer allowing it to
cool for 20 mins.
NOTE: A trip out could be caused by
low voltage supply. If tripping continues
investigate power supply as follows..........
TRANSFORMER
QUESTION: What size transformer is being used?
NOTE: Minimum transformer 2.5KW continuous rated.
Low supply voltage can cause the thermal trip to operate
NO
NO
ACTION:
110V Plug transformer direct into the
mains then the machine direct into the
transformer (No extension cables)
230V Plug the machine direct into the
mains (No extension cables)
QUESTION: Does the
machine operate normally?
YES
The mixer will only operate as designed when used with the correct supply voltage.
ALWAYS ENSURE THE CORRECT SUPPLY VOLTAGE IS USE
Entretien
NO
QUESTION: Has the machine been running
and then switched off in the last 60 mins?
YES
ACTION: Check and test the thermal protection device.
METHOD: Hold the ON button down for a minimum of 2
minutes, this will allow the fan on the motor to cool the
system.
NOTE: A trip out could be caused by low voltage
supply. If tripping continues investigate power supply as
follows..........
110 Volt
GENERATOR
QUESTION: What size generator is being used?
NOTE: Minimum output 2.2KVA continuous rated. Low
supply voltage can cause the thermal trip to operate and
QUESTION: Is extension cable being used?
QUESTION: How long is the extension cable?
NOTE: Maximum cable length 30 meters. Longer cables cause
voltage drop. Low supply voltage can cause the thermal trip to
coil.
QUESTION: Can the supply
voltage be measured safely?
INFORMATION:
230V: Minimum voltage should 218.5 Volts (-5%)
110V: Minimum voltages should be 104.5 Volts (-5%)
Low supply voltage can cause the thermal trip to operate
NO
Switch will still not hold in
A replacement switch is required
16
YES
YES
QUESTION: Is the correct
supply being used?
YES
NO
ACTION: CHECK THE
POWER SUPPLY
230 Volt
Mains supply
NO