Télécharger Imprimer la page
Empire Heating Systems FAW55SPPXLP-2 Instructions D'installation Et Manuel Du Propriétaire
Empire Heating Systems FAW55SPPXLP-2 Instructions D'installation Et Manuel Du Propriétaire

Empire Heating Systems FAW55SPPXLP-2 Instructions D'installation Et Manuel Du Propriétaire

Publicité

Liens rapides

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
NOTICE: Contact your dealer for installation, service, repair, or warranty claim
Empire Comfort Systems does not sell, service, or provide warranty directly to consumers. The consumer must contact the dealer where the
product was purchased for a warranty claim. If a non-qualified installer or consumer installs or services this product, the product warranty is
voided. Most dealers will only service products they sold so it is important for the consumer to choose a qualified dealer for installation and
warranty service. In order to maintain the warranty, service must be performed annually and documentation reviewed during the warranty request.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
FAN TYPE VENTED
WALL FURNACE MODELS:
FAW55SPPXLP - 2
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
FAW55SPPXNAT - 2
UL FILE NO.
MH46706

Publicité

loading

Sommaire des Matières pour Empire Heating Systems FAW55SPPXLP-2

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL FAN TYPE VENTED INSTALLER: WALL FURNACE MODELS: Leave this manual with the appliance. CONSUMER: FAW55SPPXLP - 2 FAW55SPPXNAT - 2 Retain this manual for future reference. WARNING FIRE OR EXPLOSION HAZARD If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2 Vent enclosure, 36” (914mm) [for rooms DV-666DB up to 118 1/2” (301cm) in height] DV648DBD 4” (102mm) Oval-to-Round flue adapter kit CONVERSION KITS Part Number Description Used On 45060 Propane to Natural FAW55SPPXLP-2 45059 Natural to Propane FAW55SPPXNAT-2 Page 2 45052-1-0823...
  • Page 3 When an existing Category 1 heater is removed or replaced, the improperly sized venting system (formation of condensate, leakage, original venting system may no longer be sized to properly vent the spillage, etc.) and shall specify the following test procedure: attached appliances.
  • Page 4 SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and Someday when there may not be a minute to lose, everyone's explosions. In its natural state, propane is odorless and safety will depend on knowing exactly what to do. If, after colorless.
  • Page 5 VENTILATION AND COMBUSTION AIR ATTENTION! This Fan Type Vented Wall Furnace is equipped Wall furnaces shall be installed in a location in which the facilities with a vent safety switch. In the event of spillage of flue products for ventilation permit satisfactory combustion of gas and proper due to improper venting the vent safety switch will open, which venting under normal conditions.
  • Page 6 5. Align clearance holes on 8” x 12” (203mm x 305mm) boot with 4” (102mm) MINIMUM 4” (102mm) MINIMUM screw holes on outer casing back and mark boot to be flush TO COMBUSTIBLES TO COMBUSTIBLES with wall surface. Remove boot and cut to proper length. 6.
  • Page 7 ATTENTION! The 7/8” (22mm) strain relief bushing is located The above connectors may be used if acceptable by the authority within the same yellow envelope as the Installation Instructions having jurisdiction. and Owner’s Manual. PRESSURE TESTING OF THE GAS SUPPLY SYSTEM ATTACHING FURNACE TO WALL 1.
  • Page 8 On a new installation with air in the gas line, it is suggested that a must be stretched to fit the motor bolts into the gasket holes and match be used. The match will light the pilot faster than the piezo then the motor and gaskets installed on the motor mounting bars.
  • Page 9 VENT SAFETY SHUT-OFF SYSTEM 2. Wries at the wall may be shorted. This appliance must be properly connected to a venting system. 3. To check for line voltage to furnace, remove lower front panel This appliance is equipped with a vent safety shut-off system. and switch compartment cover and short across two-terminal fan control to allow fan to operate (Figure 10).
  • Page 10 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted •...
  • Page 11 Model No. FAW-55 may be vented as shown. The vent cap must Use U.L. listed gas vent equipment when installing the FAW-55. For be at least 12 feet (3.7m) above the floor. Clearance to combus- vent pipe running through walls, roof, and within one (1) inch (25mm) tible construction is held by the fixed spacers at 1 inch (25mm) of combustible construction, use B-1 [one inch (25mm) clearance with B-1 vent pipe.
  • Page 12 Please Note: When ordering parts, it is very important that part number and description of part coincide. Index Part Index Part Description Description WFA115 BASEPLATE GASKET COVER PLATE FOR OBSERVATION DV064 HOLE 11763 OUTER CASING TOP DV847 BURNER DOOR NATURAL GAS R618 MOTOR MOUNT (FOUR REQUIRED) DV973...
  • Page 13 45052-1-0823 Page 13...
  • Page 14 MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 15 WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 16 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 16 45052-1-0823...
  • Page 17 INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE INSTALLATEUR : RADIATEUR MURAL À CIRCULATION FORCÉE Laissez cette notice avec l’appareil. CONSOMMATEUR : ET AVEC ÉVACUATION Conservez cette notice pour consultation ultériure. MODÈLES : FAW55SPPXLP - 2 FAW55SPPXNAT - 2 AVERTISSEMENT RISQUE D’INCENDIE OU D’EXPLOSION Si les informations contenues dans ces instructions ne sont pas suivies à...
  • Page 18 301 cm (118 1/2 po)] Kit adaptateur de fumée de 4 po (102 mm) DV648DBD ovale à rond KITS DE CONVERSION Numéro de parte La description Utilisé sur 45060 Propane to Naturel FAW55SPPXLP-2 45059 Naturel to Propane FAW55SPPXNAT-2 Page 2 45052-1-0823...
  • Page 19 Lorsqu’un radiateur de catégorie 1 existant est retiré ou remplacé, le sys- ment indiquer les effets d’un système de ventilation de taille inadéquate tème de ventilation d’origine peut ne plus être dimensionné pour ventiler (formation de condensat, fuite, déversement, etc.) et doivent spécifier la correctement les appareils raccordés.
  • Page 20 INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le Propane est un gaz inflammable qui peut causer des feux et des Lisez-les attentivement dès maintenant, puis réexaminez les, point explosions. Dans son état naturel, le propane est inodore et sans par point avec les membres de votre famille.
  • Page 21 Air de Ventilation et de Combustion Installation des Sorties Optionnelles Sur les Côtés Les radiateurs muraux doivent être installés dans un endroit où la facilité Le registre avec sortie sur le côté, SOR-1, peut être installé sur un ou les de la ventilation permet une combustion de gaz satisfaisante et un échappe- deux côtés du radiateur pourvu que les espaces libres de 18"...
  • Page 22 6. Fixer la hotte de 8" x 12" (203mm x 305mm) à la paroi extérieure arrière avec (6) vis #10 x 1/2" (13mm). Les vis sont fournies. 7. Aligner les trous libres du conduit de 6" x 10" (152mm x 254mm) avec les trous de vis de la paroi intérieure et marquer le conduit pour qu’il soit 2 1/4"...
  • Page 23 Emplacement de l'Alimentation Électrique Sur le bas des panneaux des côtés gauche et droit, il y a une entrée défon- BONDE NPT DE 1/8” (3MM) POUR VÉRIFIER LE JAUGEAGE DES çable de 7/8" (22mm) de diamètre. L’assemblage de la fiche à trois broches CONNEXIONS TUYAU D’ALIMENTATION EN GAZ (prise de terre) est situé...
  • Page 24 que les ouvertures du brûleur soient bloquées par des matières étrangères VALVE VUE DE DESSUS venant de l’air de combustion. Donc un nettoyage du brûleur peut être RÉGULATOR DE PRESSION ÉVENT exigé pour obtenir une flamme convenable. PRISE POUR SORTIE ClÉ...
  • Page 25 Pour prévenir le délai de l’évacuation aussi bien que la condensation dans Si l’interrupteur de sûreté de l’évent avec remise à zéro manuelle continu les conduits d’évacuation, nous recommandons d’isoler l’enceinte d’évent. d’arrêter le débit de gaz aux brûleurs principaux, un technicien d’entretien qualifié...
  • Page 26 POUR VOTRE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil a une veilleuse qui doit être allumée manuellement. Utiliser seulement votre main pour pousser ou tourner le bouton de Lorsque vous allumez la veilleuse, suivez exactement ces instruc- contrôle de gaz.
  • Page 27 SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN APPELER UN TECHNICIEN D’ENTRETIEN. GÉNÉRAL : Tous les radiateurs ont reçu un test d’allumage pour véri- Doit être entre 1/8" (3mm) et 3/16" (5mm). Le fil de l’électrode et fier le bon fonctionnement. Ceci inclus la flamme du brûleur principal, le bout doivent être éloignés à...
  • Page 28 S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro de Numéro Numéro de Description Description d’index la pièce d’index la pièce M148 Joint d’étanchéité pour le tuyau de gaz WFA115 Joint d’étanchéité...
  • Page 29 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 45052-1-0823 Page 13...
  • Page 30 L’évacuation du modèle FAW-55 peut se faire comme il est représenté. Le 4" B-1 Round capuchon d’évent doit être à au moins 12' (3.7m) au-dessus du plancher. Les entretoises fixes du tuyau d’évent B-1 gardent l’espace libre aux constructions combustibles à 1" (25mm). L’installation doit être conforme aux codes locaux.
  • Page 31 GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pendant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...
  • Page 32 Empire Comfort Systems Inc. Belleville, Illinois Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. www.empirecomfort.com Page 16 45052-1-0823...

Ce manuel est également adapté pour:

Faw55sppxnat-2