Empire Heating Systems GWT-50W-2 Instructions D'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
AND
GRAVITY VENTED
DUAL WALL FURNACE
MODEL
GWT-50W-2
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may
result causing property damage, personal injury or
loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Page 1

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Empire Heating Systems GWT-50W-2

  • Page 1 INSTALLATION INSTRUCTIONS OWNER'S MANUAL GRAVITY VENTED DUAL WALL FURNACE MODEL GWT-50W-2 WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Des Matières

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ..................3 Safety Information for Users of LP Gas ..............4 Introduction ......................5 Specifications ......................5 Recommended Vent Configuration ................6 Gas Supply .......................7 Clearances ......................8 Ventilation and Combustion Air ................8 Location - All Models ....................8 Rough-In Instructions ....................8-9 Finishing Instructions ..................9-10 Optional On/Off Device ..................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT OUTER CASING INSTALLED. • Due to high temperatures the appliance should be air passageways of the appliance be kept clean. located out of traffic and away from furniture and • Do not put anything around the furnace that will draperies.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone's safety will depend colorless. You may not know all the following safety precau- on knowing exactly what to do.
  • Page 5: Introduction

    INTRODUCTION Introduction Installation in Residential Garages Vented wall furnace is shipped ready to install in a 2" x 4" stud wall, Gas utilization equipment in residential garages shall be installed with studs 16" (406mm) center to center. Always consult your local so that all burners and burner ignition devices are located not less Building Department regarding regulations, codes or ordinances than 18"...
  • Page 6: Recommended Vent Configuration

    RECOMMENDED VENT CONFIGURATION Note: No vent equipment supplied with furnace. 4" Oval (all parts purchase locally) 1. Type B-1 oval pipe 2. Single story type B-1 gas vents require a baseplate and one pair of ceiling plate spacers. 3. Multi-story type B-1 gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair of fire stop spacers at each successive ceiling level.
  • Page 7: Gas Supply

    GAS SUPPLY Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 feet 1/2”...
  • Page 8: Clearances

    CLEARANCES In selecting a location for installation, it is necessary to provide from top surface of carpeting, tile, etc. adequate accessibility clearances for servicing and proper installation. Clearances to combustible surfaces are 4" (102mm) from sides, 12" (305mm) to top, 1 1/2" (38mm) from floor. NOTE: Minimum distance of 1 1/2"...
  • Page 9: Finishing Instructions

    62 1/4” (1581 mm) 14 ½” 66 1/8” (368 mm) (1679 mm) WALL OPENING Figure 2 Figure 3 FINISHING INSTRUCTIONS Plastering (Figure 4) Installing Furnace (Figure 5) In new construction use only plain (not perforated) gypsum lath Clear the recess of all debris, and remove any wood plaster-grounds. around furnace and vent pipe so that plaster "Keys"...
  • Page 10 FINISHING INSTRUCTIONS (continued) IMPORTANT — Avoid securing too tightly and disturbing the inner casing. Do not try to force furnace into a wall opening which is smaller than specified dimension. OUTER CASING (Figure 6) Align 1 3/4" slot on casing bracket with bottom screw hole on inner casing.
  • Page 11: Optional On/Off Device

    OPTIONAL ON/OFF DEVICE(SG MODELS) CAUTION — Do not run wire behind flanges of Header Plate or in TO VENT SAFETY any location where it might be damaged. Millivolt wall on/off device is specially designed for use on self- generating systems. They should never be used on line or low voltage A.C.
  • Page 12: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ bEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. C. Use only your hand to push in or turn the gas control When lighting the pilot, follow these instructions exactly.
  • Page 13: Vent Safety Shutoff System

    VENT SAFETY SHUTOFF SYSTEM This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system. Warning: Operation of this wall furnace when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.
  • Page 14: Troubleshooting

    TROUBLESHOOTING GENERAL All furnaces have been fire-tested to check for proper pilot flame or clean pilot burner. operation. This includes main burner flame, pilot flame, and gas Replace thermopile if millivolt reading is less than 300 millivolts control operation. If the furnace fails to function on initial installation, when wall mounted on/off device or remote bulb is turned it is advisable to re-check the following: OFF.
  • Page 15: Parts List

    PARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART DESCRIPTION DESCRIPTION WFA-115 HEADER GASKET BURNER ORIFICE - NAT (6 P-88-55 REQUIRED) HEADER ASSEMBLY 36324 (INCLUDES NO. 1, GASKET) BURNER ORIFICE - LPG (6 P-88-65 REQUIRED)
  • Page 16: Parts View

    PARTS VIEW Page 16 37410-0-0616...
  • Page 17: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION INSTRUCTIONS GWTB2W-1 FOR MODELS GWT-25W, GWT-35W, GWT-50W Installing blower Using Three-Prong Plug Caution: When installing blower housing onto wall be careful motor Install furnace according to Installation Instructions and Owner's coil is not damaged. Manual. Refer to Drawing for measurements to locate (2) mounting holes on wall surface above furnace.
  • Page 18 GWTB2W WIRING DIAGRAM 13” (330 mm) 4 7/16” (112.6 mm) Figure 3 Fan Control The automatic fan control is located on the bottom of the blower assembly. The fan control is a nonadjustable, automatic type. The fan control will require between 3 and 7 minutes of main burner operation before the fan control "closes"...
  • Page 19: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the peri- ods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 20 Empire Comfort Systems Inc. belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 20 37410-0-0616...
  • Page 21: Que Faire Si Vous Sentez Une Odeur De Gaz

    FournaIse à aIr chaud Par graVIté Pour Mur MItoyen Modèles gWt-50W-2 aVertIsseMent: assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
  • Page 22 table des MatIères sectIon Page Information Importante de Sécurité ..................3 Information de Sécurité pour les Utilisateurs de Propane ............4 Introduction ..........................5 Spécifications..........................5 Recommended Vent Configuration ..................6 Alimentation en Gaz .......................7 Espaces Libres ........................8 Air de Ventilation et de Combustion ..................8 Emplacement - Pour Tous les Modèles ..................8 Instructions Sommaires ......................
  • Page 23: Information Importante De Sécurité

    InForMatIon IMPortante de sécurIté cecI est un aPPareIl de chauFFage NE PAS FAIRE FoNCTIoNNER CET APPAREIL SANS qUE LA PARoI ExTéRIEURE SoIT INSTALLéE. • A cause des hautes températures, cet appareil doit être situé • Ne rien mettre autour de la fournaise qui pourrait obstruer le dans un endroit non achalandé...
  • Page 24: Information De Sécurité Pour Les Utilisateurs De Propane

    InForMatIon de sécurIté Pour les utIlIsateurs de ProPane Le propane est un gaz inflammable qui peut causer des feux et des réexaminez les, point par point avec les membres de votre famille. explosions. dans son état naturel, le propane est inodore et sans Un jour, lorsqu’il n’y aura pas une minute à...
  • Page 25: Introduction

    IntroductIon Introduction avis: Pendant le premier allumage de cette unité, la peinture cuira Lorsque la fournaise murale à air chaud est expédiée, elle est prête et de la fumée se produira. Pour prévenir les détecteurs de fumée à être installer entre les montants du mur 2" x 4" (51mm x 102mm) de se déclencher, bien ventiler l’appartement dans lequel l’unité...
  • Page 26: Configuration Recommandée Pour L'évacuation

    conFIguratIon recoMMandée Pour l’éVacuatIon note: Aucun matériel d’évacuation est fourni avec l’appareil. MINIMUM 10' (3.05m) oU Ovale de 4" (102mm) (toutes les pièces sont achetées localement) CAPUCHoN D’éVENT MoINS 1. Tuyau ovale de type B-1 ENREGISTRé Les tuyaux d’évacuation de type B-1 pour un étage exigent une plaque de base et une paire d’entretoises pour le plafond.
  • Page 27: Alimentation En Gaz

    alIMentatIon en gaZ Vérifier tous les codes locaux pour répondre aux exigences, CONNEXION D’UNE LIGNE DE GAZ FLEXIBLE spécialement pour la grandeur et le genre de ligne requise pour ALIMENTATION DE GAZ ½ MAMELON l’alimentation de gaz. TUBE FLEXIBLE ½ Le Diamètre recommandé...
  • Page 28: Espaces Libres

    esPaces lIbres note: Une distance minimum de 1 1/2" (38mm) doit aussi être 1. En choisissant un emplacement, il est nécessaire de fournir l’espace libre adéquat pour l’accès à l’installation et à l’entretien. maintenue pour le dessus des tapis, tuiles, etc. 2.
  • Page 29: Instructions Pour La Finition

    ÉVENT B AVEC UN ADAPTATEUR BW INSTALLATION ÉLECTRIQUE PERMANENTE FACULTATIVE D’UNE PRISE DE COURANT 115VOLT POUR LA SOUFFLERIE FACULTATIVE JOINT D’ÉTANCHÉITÉ POUR L’ENSEMBLE COLLECTEUR BAS DU REBORD CLOUÉ DU PLAQUE COLLECTRICE COLLECTEUR 62 ½” (1581 mm) 14 ½” PLAQUE COLLECTRICE (368 mm) 66 1/8”...
  • Page 30: Instructions Pour La Finition (Suite)

    InstructIons Pour la FInItIon (suite) Éviter de fixer la fournaise trop serrée et de pertuber la paroi in- térieure. N’essayer pas de forcer la fournaise dans une ouverture LoRSqUE LA SoUFFLERIE EST INSTALLéE, UTILISER LES 2 VIS murale qui serait plus petite que les dimensions mentionnées. ExTéRIEURES.
  • Page 31: Emplacement Du Thermostat (Modèles Sg)

    eMPlaceMent du therMostat (Modèles sg) attentIon — Ne placer pas des fils électriques derrière les TO VENT SAFETY rebords de la plaque collectrice ou quelque part où ils seraient endommagés. Installation d’un dispositif de marche/arrêt Pour installer un dispositif de marche/arrêt (tel qu’un interrupteur mural, une télécommande, un interrupteur à...
  • Page 32: Instructions D'allumage

    InstructIons d'alluMage Pour Votre sécurIté lIre aVant d’alluMer aVertIsseMent: si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. cet appareil a une veilleuse qui doit être allumée manuel- du fournisseur de gaz.
  • Page 33: Le Système De Fermeture De Sûreté De L'évent

    le systèMe de FerMeture de sûreté de l’éVent Le Système de Fermeture de Sûreté de l’Évent. L’éVENT DE SûRETé Cet appareil doit être branché correctement à un système d’évacuation. Cet appareil est muni d’un système de fermeture de sûreté de l’évent. aVertIsseMent: le fonctionnement de cette fournaise murale lorsqu’elle n’est pas branchée à...
  • Page 34: Détection Des Défectuosités

    détectIon des déFectuosItés général: Toutes les fournaises ont reçu un test d’allumage 1. Vérifier le bouton de contrôle de gaz, il doit être dans la pour vérifier le bon fonctionnement. Ceci inclus la flamme du position “Veilleuse”. brûleur principal, la flamme de la veilleuse et le fonctionnement 2.
  • Page 35: Listes Des Pièces

    lIste des PIèces attentIon: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro Description Numéro Numéro Description d’index de la pièce d’index de la pièce WFA-115 Joint d’étanchéité du collecteur R-3031 Brûleur (exige 6) 36324...
  • Page 36: Vue Des Pièces

    Vue des PIèces Page 16 37410-0-0616...
  • Page 37: Instructions Pour L'installation De La Soufflerie Facultative

    InstructIons Pour l’InstallatIon de la souFFlerIe FacultatIVe GWTB2W-1 PoUR MoDèLES GWT-25W, GWT-35W, GWT-50W l’étape 3. Installation de la Soufflerie en Utilisant une Fiche à Trois Broches 12. Placer les bouchons du châssis et de l’avant de la soufflerie. Installer la fournaise selon les Instructions pour l’Installation et Manuel 13.
  • Page 38 GWTB2W DIAGRAMME DE L’INSTALLATIoN éLECTRIqUE 1 ½” 13” (38 mm) (330.2 mm) 1 ½” (38mm) (2) TROU DE MONTAGE DE LA SOUFFLERIE (FACULTATIF) TROU D’ACCES 13mm DIA. 4 7/16 (112.6 mm) CHÂSSIS DE LA SOUFFLERIE 2 1/16” (52 mm) AVANT DE LA SOUFFLERIE Figure 3 commande du Ventilateur...
  • Page 39: Notes De Service

    notes de serVIce 37410-0-0616 Page 19...
  • Page 40 Empire Comfort Systems Inc. belleville, Il EMPIRE EMPIRE Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. Comfort Systems www.empirecomfort.com Page 20 37410-0-0616...

Table des Matières