Install Vent System; Install Leveling Legs; Level Dryer; Make Gas Connection - Whirlpool GGQ8811PW0 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Determine vent length." Avoid 90º turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure vent.

Install Leveling Legs

WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.
2. Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard.
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post under each of the 2 dryer back
corners. Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location. Leave enough room
to connect the exhaust vent.
6. Once connection is made and dryer is in final location, remove
corner posts and cardboard.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation Kit.
For ordering information please reference the "Dryer User
Instructions."
8

Level Dryer

Check the levelness of the dryer. Check levelness first
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use
a wrench to adjust the legs up or down and check again for
levelness.
NOTE: It might be necessary to level the dryer again after it is
moved into its final position.

Make Gas Connection

1. Remove the red cap from the gas pipe. Move the dryer close
to its final position.
2. Using a wrench to tighten, connect the gas supply to the
dryer. Use pipe joint compound on all non-flared male threads.
If flexible metal tubing is used, be sure there are
no kinks.
NOTE: For LP gas connections, you must use pipe joint
compound resistant to the action of LP gas. Do not use
TEFLON
®†
tape.
A combination of pipe fittings must be used to connect the
dryer to the existing gas line. Shown following is a
recommended connection. Your connection may be different,
according to the supply line type, size and location.
A
B
³⁄₈
A.
" flexible gas connector
B. ³⁄₈ " dryer pipe
C. ³⁄₈ " to ³⁄₈ " pipe elbow
D. ³⁄₈ " pipe-to-flare adapter fitting
3. Open the shutoff valve in the supply line. The valve is open
when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.