Remedy Of Faults; Wear Parts; Maintenance And Cleaning - Oase Vitronic 18 Notice D'emploi

Masquer les pouces Voir aussi pour Vitronic 18:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Remedy of faults

Malfunction
The performance of the unit is not satisfactory
UVC lamp is not lit

Wear parts

The following components are wear parts and are excluded from the warranty:
• UVC lamp, quartz glass and O ring for quartz glass

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Prior to reaching into the water, switch off the mains voltage to all units used in the water.
• Switch off the mains voltage prior to carrying out work on the unit.
Dismantling the unit head
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
• Never operate the UVC lamp outside its housing.
• Never operate the UVC lamp in a housing that is defective.
Attention! Breakable glass.
Possible consequences: Injury of your hands caused by cuts.
Protective measures: Handle both quartz glass and UVC lamp with care.
How to proceed:
5.
0.
G
1. Press the engagement hooks.
2. Turn the unit head counter-clockwise as far as the stop and carefully pull it out of the casing.
• Thoroughly clean the inner and outer surfaces of the casing.
Note!
For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into
the casing.
Fitting the unit head
How to proceed:
3.
0.
H
1. Check the O ring at the unit head for correct seating.
− Clean the O ring, replace if damaged.
2. Carefully push the unit head into the casing up to the stop while applying slight pressure.
− Turn the unit head slightly so that the tenons and grooves of the bayonet closure intermesh.
3. Turn the unit head clockwise up to the stop.
23929-11-13_GA_Vitronic 18_USA.p7 7
Cause
The water is extremely soiled
The quartz glass is soiled
The UVC lamp capacity is exhausted
Flow rate is too high
Power plug not connected
UVC lamp defective
Connection defective
- English -
Remedy
Remove algae and leaves from the pond,
change the water
Clean the quartz glass
The lamp must be replaced after 8000 operat-
ing hours
Reduce the pump output
Connect power plug
Replace the UVC lamp
Check electrical connection