Door Access
DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE
UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING
JURISDICTION. Doing so may cause interference with the
operation of panic hardware.
*PRIMARY RELAY
DOOR STRIKE
Power for Door Strike
Use 18-22 AWG
For DC Power:
Install a 1N4005
OR
diode or equivalent
MAGLOCK
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
All manuals and user guides at all-guides.com
OUTPUT
WIEGAND
1
OUTPUT
2
GATE
SDA SCL
NO COM NC
NO COM NC
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
(provided) or equivalent
(Not Provided)
COMMON
+
NORMALLY OPEN
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NORMALLY CLOSED
COMMON
+
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
Not responsible for conflicts between the information listed in
the wiring diagram and the requirements of your local building
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
INPUT
1
WIEGAND
2
INPUT
D1 COM D0
D1 COM D0
1 GND 2
GND 12V-24V
(NON-SUPERVISED)
AUXILIARY RELAY
Low
Voltage
Power
Supply
Isolation
Relay
COMMON
NORMALLY OPEN
POWER
POWER
ETHERNET
SUPERVISED (DOOR STATUS)
DOOR SENSOR
OR
EOL (End of Line) Resistor
(1k ohm)
LIGHT
LOAD
LINE
NOTE: For UL
installations, only UL
294 Listed electric
OR
door strikes or UL
ALARM BYPASS
294 Listed Maglocks
may be connected to
relay output 1 or 2.
DOOR SENSOR
(SUPERVISED)