Télécharger Imprimer la page

Publicité

Liens rapides

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
NOTICE: Contact your dealer for installation, service, repair, or warranty claim
Empire Comfort Systems does not sell, service, or provide warranty directly to consumers. The consumer must contact the dealer where the
product was purchased for a warranty claim. If a non-qualified installer or consumer installs or services this product, the product warranty is
voided. Most dealers will only service products they sold so it is important for the consumer to choose a qualified dealer for installation and
warranty service. In order to maintain the warranty, service must be performed annually and documentation reviewed during the warranty request.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
FAN TYPE VENTED
WALL FURNACE MODELS:
FAW55IPXLP - 2
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
FAW55IPXNAT - 2
UL FILE NO.
MH46706

Publicité

loading

Sommaire des Matières pour Empire Heating Systems FAW55IPXLP-2

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL FAN TYPE VENTED INSTALLER: WALL FURNACE MODELS: Leave this manual with the appliance. CONSUMER: FAW55IPXLP - 2 FAW55IPXNAT - 2 Retain this manual for future reference. WARNING FIRE OR EXPLOSION HAZARD If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2 TABLE OF CONTENTS SECTION PAGE Introduction..........................3-4 Safety Information For Users Of Propane Gas ................5 Installation ..........................6-10 Lighting Instructions ........................11 Service And Maintenance Suggestions ................... 12-13 Troubleshooting ..........................14 S8600H Troubleshooting Guide ....................15-16 Venting ............................17 Parts List ............................
  • Page 3 Vent enclosure, 36” (914mm) [for rooms up to DV-666DB 118 1/2” (301cm) in height] DV648DBD 4” (102mm) Oval-to-Round flue adapter kit CONVERSION KITS Part Number Description Used On 682160 Propane to Natural FAW55IPXLP-2 682269 Natural to Propane FAW55IPXNAT-2 45053-0-0523 Page 3...
  • Page 4 INTRODUCTION (CONT’D) When an existing Category 1 heater is removed or replaced, also indicate effects of an improperly sized venting system the original venting system may no longer be sized to (formation of condensate, leakage, spillage, etc.) and shall properly vent the attached appliances. Instructions shall specify the following test procedure: WARNING CARBON MONOXIDE POISONING HAZARD...
  • Page 5 SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and Someday when there may not be a minute to lose, everyone's explosions. In its natural state, propane is odorless and safety will depend on knowing exactly what to do. If, after colorless.
  • Page 6 INSTALLATION Ventilation and Combustion Air Attention! This Fan Type Vented Wall Furnace is equipped with Wall furnaces shall be installed in a location in which the facilities a vent safety switch. In the event of spillage of flue products for ventilation permit satisfactory combustion of gas and proper due to improper venting the vent safety switch will open, which venting under normal conditions.
  • Page 7 INSTALLATION (CONT’D) Installing Optional Rear Outlet 4” (102mm) OVAL TYPE “B” VENT CENTER TO COMBUSTIBLES CONNECTION Rear outlet kit, 10” (254mm) boot assembly with register, ROK-1 VENT CENTER TO MINIMUM CLEARANCE 1-9/16” (40mm) COMBUSTIBLES MINIMUM for warm air discharge into an adjoining room. CLEARANCE 1-9/16”...
  • Page 8 INSTALLATION (CONT’D) Locating Furnace On Wall Compounds used on threaded joints of gas piping shall be resistant The furnace is to be located on a wall. The furnace is 16 inches to the action of liquefied petroleum gases. The gas lines must be (406mm) in width and normal 16 inches (406mm) on center studs checked for leaks by the installer.
  • Page 9 INSTALLATION (CONT’D) Checking Manifold Pressure Both Propane and Natural Gas valves have a built-in pressure regulator in the gas valve. Natural Gas models will have a manifold pressure of approximately 3.5” w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 5.0” w.c. (1.24kPa) for the purpose of input adjustment to a maximum of 10.5”...
  • Page 10 INSTALLATION (CONT’D) Wiring Vent Safety Shut-Off System The appliance, when installed, must be electrically grounded in This appliance must be properly connected to a venting system. accordance with local codes or, in the absence of local codes, with This appliance is equipped with a vent safety shut-off system. the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical WARNING Code, CSA C22.1, if an external electrical source is utilized.
  • Page 11 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which C.
  • Page 12 SERVICE & MAINTENANCE SUGGESTIONS CALL SERVICEMAN GENERAL: All furnaces have been fire-tested to check for proper STEP 1: Perform Visual Inspection. operation. This includes, main burner flame, pilot flame, fan A. With power off, make sure all wiring connections are clean and operation, fan control, limit control and automatic valve operation.
  • Page 13 SERVICE & MAINTENANCE SUGGESTIONS If the pilot does not light, or the pilot flame current is not at least 1.0 sensing circuit in the module detects the flame current, shuts off uA and steady, the module will not energize the second main valve the spark generator and energizes the second main valve operator.
  • Page 14 TROUBLESHOOTING Important WARNING 1. The following service procedures are provided as a general guide. When performing the following steps, do not touch stripped 2. Meter readings between gas control and ignition module must end of jumper or SPARK terminal. The ignition circuit generates be taken within the trial for ignition period.
  • Page 15 S8600H TROUBLESHOOTING GUIDE • Check line voltage power, low voltage transformer, limit controller, and writing. • Also, check air proving switch on combustion air blower system (if used) and that the end switch (if used) is made. 45053-0-0523 Page 15...
  • Page 16 S8600H TROUBLESHOOTING GUIDE GREEN LED STATUS CODES Green LED Flash Code Indicates Next System Action Recommended Service Action (X + Y) No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None Recycle...
  • Page 17 VENTING Model No. FAW-55 may be vented as shown. The vent cap must Use U.L. listed gas vent equipment when installing the FAW-55. For be at least 12 feet (3.7m) above the floor. Clearance to combustible vent pipe running through walls, roof, and within one inch (25mm) construction is held by the fixed spacers at 1 inch (25mm) with B-1 of combustible construction, use B-1 (one inch (25mm) clearance vent pipe.
  • Page 18 PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index Part Index Part Description Description WFA115 Baseplate Gasket DV847 Burner Door Natural Gas 11763 Outer Casing Top DV972 Burner Door Propane Gas R618 Motor Mount (Four Required) 45069...
  • Page 19 PARTS VIEW 45053-0-0523 Page 19...
  • Page 20 MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 21 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 45053-0-0523 Page 21...
  • Page 22 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 22 45053-0-0523...
  • Page 23 WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 24 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 24 45053-0-0523...
  • Page 25 INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE INSTALLATEUR : RADIATEUR MURAL À CIRCULATION FORCÉE Laissez cette notice avec l’appareil. CONSOMMATEUR : ET AVEC ÉVACUATION Conservez cette notice pour consultation ultériure. MODÈLES : FAW55IPXLP - 2 FAW55IPXNAT - 2 AVERTISSEMENT RISQUE D’INCENDIE OU D’EXPLOSION Si les informations contenues dans ces instructions ne sont pas suivies à...
  • Page 26 301 cm (118 1/2 po)] Kit adaptateur de fumée de 4 po (102 mm) DV648DBD ovale à rond KITS DE CONVERSION Numéro de parte La description Utilisé sur 682160 Propane to Naturel FAW55IPXLP-2 682269 Naturel to Propane FAW55IPXNAT-2 Page 2 45053-0-0523...
  • Page 27 Lorsqu’un radiateur de catégorie 1 existant est retiré ou remplacé, le sys- ment indiquer les effets d’un système de ventilation de taille inadéquate tème de ventilation d’origine peut ne plus être dimensionné pour ventiler (formation de condensat, fuite, déversement, etc.) et doivent spécifier la correctement les appareils raccordés.
  • Page 28 INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le Propane est un gaz inflammable qui peut causer des feux et des Lisez-les attentivement dès maintenant, puis réexaminez les, point explosions. Dans son état naturel, le propane est inodore et sans par point avec les membres de votre famille.
  • Page 29 2. Ce radiateur ne doit pas être branché à une cheminée servant Air de Ventilation et de Combustion à un autre appareil brûlant un combustible solide. Les radiateurs muraux doivent être installés dans un endroit 3. Les tuyaux de métal à simple paroi non-isolée ne doivent où...
  • Page 30 Installation d’une Sortie Arrière Optionnelle L’assemblage de sortie arrière, l’assemblage de la hotte de 10" TOUTES LES CONNEXIONS DOVIENT ÉTRE FAITES MÉCANIQUEMENT ET LES ESPACES LIBRES INDIQUES (254mm) avec registre, ROK-1 pour l’évacuation d’air chaud DOIVENT ÉTRE OBSERVÉS dans une pièce voisine. Attention! Avant de fixer le radiateur au mur, vous devez couper l’ouverture dans le mur pour la sortie arrière, en plus d’enlever les entrées défonçables de la paroi extérieure et intérieure du...
  • Page 31 Ne pas serrer trop fort les vis et déformer le bas de la paroi exté- MINIMUM 102MM MINIMUM 102MM AUX COMBUSTIBLES AUX COMBUSTIBLES rieure. Déformer le bas de la paroi extérieure vous empêchera de fixer le panneau du bas avant, au radiateur. Alimentation en Gaz Vérifier tous les codes locaux pour répondre aux exigences, spécialement pour la grandeur et le genre de ligne d’alimentation...
  • Page 32 L’emploi des connexions de gaz suivantes est recommandé: assez grande pour couvrir complètement la zone d’étincelle. — ANS Z21.24 Connexions d’appareil de tuyaux et de raccords Seulement 2 ou 3 étincelles apparaîtront lorsque la flamme sera en métal ondulé. convenable. Plus d’étincelles indiquera une petite flamme de —...
  • Page 33 faire entrer de l’eau avec force dans la bande d’ouvertures et Les radiateurs muraux avec un évent, installés dans des bâtiments ayant un toit plat, peuvent avoir une évacuation inadéquate. sécher avec une pression d’air. Lorsque le tuyau d’évent est froid, un délai de l’évacuation convenable se fera et entraînera l’interrupteur de sûreté...
  • Page 34 remise à zéro manuelle. SYSTÈME DE FERMETURE DE SÛRETÉ DE L’ÉVENT 1. Enlever le panneau de devant en haut. 2. Abaisser le bouton rouge de remise à zéro manuelle. L’interrupteur de sûreté de l’évent avec une remise à zéro manuelle est situé sur le coupe-tirage. 3.
  • Page 35 POUR VOTRE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. C. Utiliser seulement votre main pour pousser ou tourner le bouton A.
  • Page 36 SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN. APPELER UN TECHNICIEN D’ENTRETIEN GÉNÉRAL: Tous les radiateurs ont reçu un test d’allumage pour vérifier B. Mettre le pouvoir en circuit à l’appareil et au module d’allumage. le bon fonctionnement. Ceci inclus la flamme du brûleur principal, la Ouvrir les valves de fermeture manuelles pour la ligne de gaz de flamme de la veilleuse, le fonctionnement du ventilateur, le contrôle l’appareil.
  • Page 37 Verrouillage de Sûreté. s’ouvre et le gaz se dirige vers le brûleur principal lequel est allumé par le S8600H assure un arrêt efficace à 100 pourcent ou un verrouillage de brûleur de la veilleuse. Aussi le courant de la flamme garde la minuterie sûreté.
  • Page 38 DÉTECTION DES DÉFECTUOSITÉS Important AVERTISSEMENT 1. Les procédures d’entretien suivantes sont fournies comme étant un Lorsque vous exécutez les étapes suivantes, ne toucher pas à guide général. l’extrémité dénudée du pont ou de la borne d’étincelle. Le circuit 2. Les lectures des compteurs entre l’accélérateur et le module d’allumage produit un courant électrique de 13,000 volts à...
  • Page 39 DÉPART Note: A vant de détecter les défectuosités, familiarisez-vous avec la mise en marche et les procédures de vérification Fermeture de l'alimentation de gaz. Turn (contrôleur) pour appeler à la chaleur Vérifier le pouvoir de la ligne de tension, le transformateur à basse ten- Pouvoir du module sion, le contrôle de tolérance, le thermostat et l'installation électrique.
  • Page 40 S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro Numéro Numéro d’Index de la Pièce d’Index de la Pièce Description Description WFA-115 DV-064 Joint d’étanchéité de la plaque de base Plaque de couverture pour l’ouverture d’observation 11763 DV-847...
  • Page 41 Empire Comfort Systems, Inc. Belleville, Illinois 45053-0-0523 Page 17...
  • Page 42 L’évacuation du modèle FAW-55 peut se faire comme il est Lorsque vous installez le FAW-55, utiliser de l’équipement d’évent représenté. Le capuchon d’évent doit être à au moins 12' (3.7m) à gaz U.L. admis. Pour les tuyaux d’évent traversant les murs, au-dessus du plancher.
  • Page 43 GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pendant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...
  • Page 44 Empire Comfort Systems Inc. Belleville, Illinois Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. www.empirecomfort.com Page 20 45053-0-0523...

Ce manuel est également adapté pour:

Faw55ipxnat-2