Specifications
Model
Type of apparatus
Power Supply
Recommend battery type
Sensor Type
Product Life
Sensitivity Setting
Standby Current
Alarm Current
Operation Ambient Condition
Storage/Transport Ambient Condition : -20 ~ +50°C, 10 ~ 95% non-condensing
Alarm Sound
CO Alarm Silence
Other Warning Silence
Installation Location
Detection Range
NOTE:
-
This CO alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect
any other gas.
12.
Symbols
Recycling and Disposal: The WEEE symbol indicates that this product and its batteries must be disposed of separately
from household waste. When this product reaches the end of its service life, take it to a designated waste collection
point nearby to ensure safe disposal or recycling. Protect the environment and human health, use natural resources
responsibly!
Updates or new warmings might apply to the manual. Always check the most up to date manual on www.elro.eu
before installing or reinstalling the product. Read the manual before use and keep it in a safe place for future use
and maintenance.
Guarantee vi
sit www.elro.eu
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam - The Netherlands
: FC4902R
: Type B
: DC 3V (2pcs alkaline battery)
: GP GN15A / Raymax LR6
(For 3 years battery life at normal operation)
: Electrochemical
: 10 years after activation
: Conforms to EN 50291-1:2018 standard.
030PPM Without alarm before 120 minutes
050PPM Between 60 to 90 minutes
100PPM Between 10 to 40 minutes
300PPM Less than 3 minutes
: <20μA (average)
: <30mA (average)
: -10 ~ +40°C, 30 ~ 95% non-condensing
: ≥85DB at 3m @3.2±0.5KHz pulsing alarm
: About 10 minutes
: About 9 hours
: Ceiling or wall of domestic premises
: Max. 40 m2 within a room