Installation and Operation Manual
cegard/Mini with selectable output logic
Emitter (Tx) Connections
Emitter/
Tx edge
Application:
If there a parts in the door construction (e.g. doorcam) which are moving through the protection field during door closure
certain elements of the light curtain have to be disabled.
Important:
1. This setting does not fulfill EN 81-70
2. Blanking function is not possible with reduced protection field (see page 3)
5.
Power-up and test for correct function
Turn on power after cegard/Mini has been correctly installed. In each edge (Rx and Tx) there is one optical
indicator (green LED) which indicates the light curtain status.
* This blanking function is not available in the USA and in Canada. With one broken element system works without criss cross beams
© CEDES I V 2.3
Receiver/
Emitter/
Rx edge
Tx edge
Edge
LED Color
LED ON
Power OK
Rx
Orange
Object detected
Tx
Green
Power OK
Rx cable connection for NO
Brown:
Blue:
Black:
White:
Rx cable connection for NC
Brown:
Blue:
Black:
White:
Tx cable connection
for standard protection field heigth: 1,822mm
Brown:
Blue:
Black:
White:
Tx cable connection
for reduced protection field heigth: 1,582mm
Brown:
Blue:
Black:
White:
Receiver/
Rx edge
LED OFF
No Power or
No object
No Power
www.cedes.com
cegard/Mini
U
= +14 ... 30 VDC
SP
GND (0 V)
Output to door operator / elevator
controller
Selector connected to GND
U
= +14 ... 30 VDC
SP
GND (0 V)
Output to door operator / elevator
controller
Selector connected to U
not connected
+14 ... 30 VDC
GND (0 V)
n.c
Height Selector not connected
or connected to GND (blue)
+14 ... 30 VDC
GND (0 V)
n.c
Height Selector connected to U
(brown)
LED flashing
1 element broken*
(Muting function, page 3)
-
or
SP
SP
5