All manuals and user guides at all-guides.com
Ex appoval - 5343a:
KEMA 10ATEX0004 X ..................................
ATEX Installation Drawing No. ................ 5343QA02
Ex / i.s. approval - 5343B:
KEMA 03ATEX1538 .....................................
Max. amb. temperature for T4 .................... 85°C
Max. amb. temperature for T6 ................... 60°C
ATEX, applicable in zone ............................. 0, 1, 2, 20, 21 or 22
ATEX Installation Drawing No. ................ 5343QA01
marine approval:
Det Norske Veritas, Ships & Offshore ......... Standard for Certification No. 2.4
gosT R approval:
VNIIM & VNIIFTRI, Cert. no. ........................ See www.prelectronics.com
observed authority requirements:
EMC 2004/108/EC ...................................... EN 61326-1
ATEX 94/9/EC .............................................. EN 60079-0, EN 60079-11,
II 3 GD Ex nA [nL] IIC T4...T6 or
II 3 GD Ex nL IIC T4...T6 or
II 3 GD Ex nA [ic] IIC T4...T6 or
II 3 GD Ex ic IIC T6...T4
II 1 G Ex ia IIC T4 or T6
II 1 D Ex iaD
standard:
EN 60079-15 and EN 60079-26
EN 61241-0 and EN 61241-11
5343V103-IN
19