Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11

Liens rapides

DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 2006/95/EC. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 +
A15:2011).
– Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
– Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
– Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.
í Cooling Maximum conditions
Outdoor temperature :
Room temperature :
í Cooling Minimum conditions
Outdoor temperature :
Room temperature :
Tools required for installation (not supplied)
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 8
Power Supply:
220 - 240 V ~ 50 Hz
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with
a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
INSTALLATION INSTRUCTIONS
as it satisfies Directives:
OPERATING LIMITS
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
19.Hammer
10.Drill
11. Tube cutter
12.Tube flaring tool
13.Torque wrench
14.Adjustable wrench
15.Reamer (for reburring)
16.Hex. key
37.4255.122.01
- Split system air conditioner -
í Heating Maximum conditions
Outdoor temperature :
Room temperature :
í Heating Minimum conditions
Outdoor temperature :
Room temperature :
Model Combinations:
SEE CATALOGUE
ASIAS8DC
ASGIDC (FRAME GRILLE)
ASIBS9DC
ASICS10DC
ASGI25DC (FRAME GRILLE)
ASIDS13DC
ASGI48DC (FRAME GRILLE)
01/2017
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
EG
I
F
D
E
P
GR
Table des Matières
loading

Sommaire des Matières pour Technibel ASIAS8DC

  • Page 11: Climatiseur Split

    Température extérieure : –15°C B.S. Outillage necessaire à l'installation (non livré) Combinaison de modèles: 1.Tournevis à tête plate 19.Marteau VOIR LE CATALOGUE 2.Tournevis moyen 10.Perceuse cruciforme 11. Coupe-tubes ASIAS8DC ASGIDC (GRILLE) 3.Pince à dénuder 12.Dudgeonnière pour ASIBS9DC 4.Mètre connexion flares ASICS10DC ASGI25DC (GRILLE) 5.Niveau 13.Clé...
  • Page 12 DIMENSIONS (mm) ASIAS8-ASIBS9 Brides de suspension Brides de suspension Plafond Côté reprise de l’air extérieure BRIDES DE SUSPENSION Tige de suspension Plafond Boîte des composants électriques Ecrous et rondelles Côté tubes frigorifique COTE TUBE FRIGORIFIQUE Raccord tube frigorifique (tube PETIT) Raccord tube frigorifique (tube GROSS) Raccord sortie des condensâtes...
  • Page 13 DIMENSIONS (mm) ASICS10-ASIDS13 Modèle ASICS10 ASIDS13 1050 1150 Poids net Modèle ASICS10 ASIDS13 Unité 23 kg 29 kg Ensemble façade / grille 5 kg 7 kg A Orifice condensats : Ø 32 mm extérieur B Entrée C Sortie...
  • Page 14: Veuillez Lire Ce Qui Suit Avant De Commencer

    IMPORTANT! • Effectuez la mise à la terre de l'appareil en respectant les réglementations électriques locales. Veuillez lire ce qui suit avant de commencer • Le câble jaune/vert ne peut en aucun cas être utilisé pour Ce système de conditionnement de l'air répond à des toute autre connexion que celle de la mise à...
  • Page 15 Choix de l'emplacement d'installation - Appareil intérieur RECHERCHEZ • Un emplacement approprié à partir duquel l'ensemble de la EVITEZ pièce peut être climatisé de manière uniforme. • L'exposition directe au soleil. • Un emplacement suffisamment solide pour supporter le poids •...
  • Page 38 ASIAS8-ASIBS9 Before installing the unit, place the tubes, the electrical wires and the condensate drain pipe in the proper position for the connection. Adjust the distance between the unit and the ceiling (max 23 mm) using the nuts of the four suspension bolts. Verify also the distance between the suspension bracket and the ceiling...
  • Page 39 ASICS10-ASIDS13 SUSPENDING THE UNIT AT THE CEILING • Use the drilling template provided (2) to determine the position of the suspension rods (1) and the hole to be made in the false figure 01 ceiling (figure 01). For the suspension rods, use dia. 8 or 10mm threaded rod. •...
  • Page 41 ASIAS8-ASIBS9 INSTALLATION OF THE CONDENSATE DRAIN PIPE. Utilise a hard, well insulated PVC pipe (I.D. 18 mm) and fix it to the unit using a flexible PVC or gummy hose ; tighten firmly with hose bands The connection must be well insulated, using foamed polyethylene (thickness 8mm).
  • Page 42 ASICS10-ASIDS13 INSTALLATION OF THE CONDENSATE DRAIN PIPE. Connect to the unit’s drain fitting (1) a hard, well insulated PVC pipe (4) (I.D. 32 mm) and fix it to the unit using a flexible PVC or gummy hose (2); tighten firmly with hose bands (3). The connection must be well insulated, using foamed polyethylene (thickness 8mm).
  • Page 43 • If it is necessary to increase the height of the drain pipe somewhat, the portion directly after the connection port can be raised a maximum of 25/30 cm. Do not raise it higher than this limit , as this could result in water leaks.
  • Page 46 L’unità é predisposta per il collegamento di un condotto per l’aria di rinnovo. Il ventilatore ausiliario per l’aspirazione dell’aria esterna deve essere alimentato separatamente e comandato tramite un interruttore bipolare ON-OFF con fusibili di protezione. La portata d’aria esterna deve essere circa il 10% della portata d’aria totale, al fine di evitare malfunzionamento e rumorosità.
  • Page 47 Predispose the terminals of the wire to connect to the terminal strip and connect them. (See electric wiring to connect). Secure inter-unit wire using the supplied clamp. WARNING Loose wiring may cause the terminal to overheat or result in unit malfunction.
  • Page 50 Câble de raccordement B (BLINDE): Câble électrique bipolaire blindé: la section et la longueur du câble électrique recommandé sont indiquées dans la notice d’installation de l’unité extérieure. Le câble doit être de type H05VVC4V5-K minimum (selon CEI 20-20 CENELEC HD21). Câble de raccordement C (avec mise à...
  • Page 51: Posizione Del Telecomando

    REMOTE CONTROL UNIT INSTALLATION • POSIZIONE DI INSTALLAZIONE TELECOMANDO • EMPLACEMENT DE LA COMMANDE A DISTANCE • POSITION DER FERNBEDIENUNG • POSICION DE INSTALACION DEL MANDO A DISTANCIA • POSIÇÃO DA INSTALAÇÃO DA UNIDADE DE CONTROLE REMOTO • Q Q E E S S H H T T O O P P O O Q Q E E T T H H S S H H S S T T H H L L E E C C E E I I R R I I S S T T H H R R I I O O U U REMOTE CONTROL UNIT INSTALLATION To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places: •...
  • Page 52 WALL-MOUNTED POSITION • Momentarily place the remote control unit in the desired mounting position. • Verify that the remote control unit can operate from this position. • Fix the support at the wall with two screws and hang the remote control unit. POSIZIONE A PARETE •...
  • Page 53 DEFAULT SETTING RESET - RESET IMPOSTAZIONI DI DEFAULT - REMISE A ZERO DES REGLAGES DE DEFAUT - ZURÜCKSETZEN AUF STANDARDEINSTELLUNGEN - RESTABLECER LA CONFIGURACIÓN PREDETERMINADA - RESTABLECIMENTO DAS CONFIGURAÇÕES DE FABRICA - ∂ ·Ó·ÊÔÚ¿ ÛÙ¿ÓÙ·ÚÙ Ú˘ıÌ›ÛÂˆÓ To operate the unit again with the default setting it is necessary to set the remote control as follows: Filter: ON Night Mode / High Power Mode: OFF Operation mode: AUTO...
  • Page 55 PUMP DOWN (See Installation Instruction of Outdoor Unit) Pump down means collecting all refrigerant gas in the “Pump down” significa: recuperar todo el gas system back into the outdoor unit without losing gas. refrigerante en la Unidad Exterior sin perder la carga Pump down is used when the unit is to be moved of del Sistema.
  • Page 62 ADRESSE DU CIRCUIT DE REFRIGERATION UNITE EXTERIEURE/INTERIEURE Les unités intérieures qui font partie d'un système multisplit doivent être configurés correctement pour communiquer avec l'unité extérieure sur plusieurs canaux (unité intérieure A, unité intérieure B, etc ...) du bus de communication. Chaque adresse de l'unité...
  • Page 63: Reglage Des Adresses Avec La Telecommande (Jusqu'a 8 Unites Interieures)

    (2) REGLAGE DES ADRESSES AVEC LA TELECOMMANDE (JUSQU’A 8 UNITES INTERIEURES) Régler la télécommande comme indiqué dans le tableau. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C flap...
  • Page 64: Procedure D'adressage Automatique

    (3) PROCEDURE D’ADRESSAGE AUTOMATIQUE Exigences du système: L'unité extérieure doit avoir une version récente du firmware qui prend en charge la procédure d'adressage automatique. Les unités intérieures doivent avoir une version récente du firmware qui prend en charge la procédure d'adressage automatique.
  • Page 74 d d i i e e u u q q u u v v n n s s e e w w n n E E x x w w t t e e r r i i k k e e v v " " m m o o n n a a v v d d e e " " - - E E s s w w t t e e r r i i k k e e v v " " m m o o n n a a v v d d e e " " √È...
  • Page 76 (3) ∞ÀΔ√ª∞Δ∏ ƒÀ£ªπ™∏ ¢π∂À£À¡™∏™ ∞ ·ÈÙ‹ÛÂȘ Û˘ÛÙ‹Ì·ÙÔ˜: ∏ Â͈ÙÂÚÈ΋ ÌÔÓ¿‰· ı· Ú¤ ÂÈ Ó· ¤¯ÂÈ Ì›· ÚfiÛÊ·ÙË ¤Î‰ÔÛË ˘ÏÈÎÔÏÔÁÈÛÌÈÎÔ‡ Ô˘ Ó· ˘ ÔÛÙËÚ›˙ÂÈ ÙËÓ ‰È·‰Èηۛ· ·˘ÙfiÌ·Ù˘ Ú‡ıÌÈÛ˘ ‰È‡ı˘ÓÛ˘. √È ÂÛˆÙÂÚÈΤ˜ ÌÔÓ¿‰Â˜ ı· Ú¤ ÂÈ Ó· ¤¯Ô˘Ó Ì›· ÚfiÛÊ·ÙË ¤Î‰ÔÛË ˘ÏÈÎÔÏÔÁÈÛÌÈÎÔ‡ Ô˘ Ó·...
  • Page 77 REFRIGERANT CIRCUIT CHECK • CONTROLLO CIRCUITO REFRIGERANTE • CONTROLE DU CIRCUIT DE REFRIGERATION • NACHPRÜFUNG DER KÜHLROHRE • COMPROBACIÓN DEL CIRCUITO DE REFRIGERACIÓN • VERIFICAÇÃO DE TUBAGENS DE REFRIGERANTE • ¢π∞¢π∫∞™π∞ ƒÀ£ªπ™∏™ æÀ∫Δπ∫√À ∫À∫§øª∞Δ√™ 1. Power ON the system. 2. Set the remote controller of unit A as following (units B, C and D must be OFF): -Mode: COOLING -Filter: ON -Set-point: 32°C...
  • Page 79 MATCH BETWEEN REMOTE CONTROLLER AND INDOOR UNIT • ABBINAMENTO TRA TELECOMANDO E UNITA’ INTERNA • COMBINAISON ENTRE TELECOMMANDE ET UNITE INTERIEURE • KOMBINATION ZWISCHEN FERNBEDIENUNG UND INNENEINHEIT • COMBINACION ENTRE MANDO A DISTANCIA Y UNIDAD INTERIOR • COMBINAÇÃO ENTRE UNIDADE DE CONTROLE REMOTO E UNIDADE INTERIOR • d d i i e e u u q q u u v v n n s s e e w w n n ÙËϯÂÈÚÈÛÙ‹ÚÈÔ - - E E s s w w t t e e r r i i k k e e v v "...
  • Page 80 Set SW1 as shown in the table. Impostare SW1 come indicato in tabella. Régler SW1 comme indiqué dans le tableau. Stellen Sie SW1 ein, wie in der Tabelle gezeigt ist. Regular SW1 como indicado en la tabla. Ajustar SW1 como mostrado na tabela. ƒ˘ıÌ›ÛÙÂ...
  • Page 82 PREPARATION DE LA TELECOMMANDE Retirez le couvercle en plastique de la borne de la télécommande. Ouvrez le compartiment des piles, retirer les piles et régler les interrupteurs 5 et 6 en la position OFF. Fermez le compartiment des piles sans mettre les piles (la télécommande sera alimentée par le câble). LIAISON Utilisez un câble électrique tripolaire blindé...

Ce manuel est également adapté pour:

Asibs9dcAsics10dcAsids13dcAsgi48dcAsgi25dcAsgidc

Table des Matières