230V 50Hz (L=phase, N=neutral) power supply input
L
N
3
1 Common contact
COM1
4
1 usually closed contact
NC1
5
1 usually open contact
NO1
6
2 usually closed contact
NC2
7
2 usually open contact
NO2
8
2 common contact
COM2
9-10
12V
12V
11
Common input
COM
Input 1, if activated it can cause the relay closing or opening according to the opera-
ting selected program (see table 2).
12
IN1
It can be activated by pushing a simple key N.O., through a remote, or applying a
tension of 12/24V ~/
Input 2, if activated can cause the relay closing or opening, according to the opera-
ting selected program (see table 2).
13
IN2
It can be activated by pushing a simple key N.O., through a remote, or applying a
tension of 12/24V ~/
Contact input N.C. "enable" : must be bridged towards the COM, when open every
14
INE
command via radio or applied to IN1 and IN2 input is ignored.
Aerial signal input
15
Aerial ground input
16
Select IN2 input:
J5=A IN2 is controlled by a 12/24V ~/
J5
A
B
J5=B IN2 is controlled by an N.O. contact
Select IN1 input:
J5=A IN2 is controlled by a 12/24V ~/
J6
A
B
J5=B IN2 is controlled by an N.O. contact
8

OPERATING INSTRUCTIONS

8.1 Description of operating programs
SSE12 feeder provides 3 different working programs that can be selected through dipswitch S1, as
indicated in table2. For the programming of "delay on" and "delay off" refer to par. 8.2 "Learning of
temporizing".
Table 1 terminal boards connection
max 300mA input; 9 = +, 10 = -
respect the COM clamp.
respect the COM clamp.
Operating instructions and warnings
only for qualified personnel
tension
tension