NATURAL GAS CONVERSION INSTRUCTION
9
1
2
Slip sleeve over the end of burner tube and cover the LP primary air hole,
10
then screw it.
11
NG Orifice Spud
Bellows
Disconnect the bellows.
Disconnect the LP orifice spud from the Burner tube.
LP Orifice Spud
Bellows
Sleeve
Find the new NG orifice spud, verify it is the correct size, the sign 3.86mm
(3.9mm for OFG107 Rock Fire Table ) should be on the side of the orifice spud.
1
Screw the new NG orifice spud into Burner tube.
Re-attach bellows to the NG orifice spud.
2
1
2
Burner Tube
LP Primary Air Hole
2
1
8 / 40
Burner Tube
After