Use with with Valor Models MF28I & MF28J Heaters ONLY
Once converted to NG, this appliance is certifi ed for
use from 0–4500 feet. For altitudes above 4500 feet,
see local codes.
Kit Contents
1 Pilot injector (marked 35)
1 Burner
1 Injector (marked 750)
1 Set of conversion labels
1 Set of air shutters
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module &
pilot shield
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
• Manometer, to set manifold at the valve
Rating
Maximum 26,000 Btu/hr
Minimum 6,500 Btu/hr
General notes regarding conversion
The conversion may be done before or after the
appliance is installed into the cavity. However, the
gas must be connected in order to set the manifold
pressure.
4002175-03
M
ADRONA
Natural Gas Conversion Kit
MA28INK
Installation Instructions
© 2016, Miles Industries Ltd. All rights reserved.
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
loading

Sommaire des Matières pour Valor MADRONA Serie

  • Page 4: Kit De Conversion Au Gaz Naturel

    LE PREMIER FOYER À GAZ RADIANT Kit de conversion au gaz naturel MA28INK Utilisez avec les foyers Valor MF28I et MF28J SEULEMENT Directives d’installation Une fois converti au gaz naturel, cet appareil est AVERTISSEMENT homologué pour fonctionner de 0 à 4 500 pieds. Pour Ce kit de conversion doit être installé...
  • Page 5 Procédure de conversion 6. Enlevez les 6 vis—dont 2 sous les supports— retenant les supports du brûleur à la plaque. 1. Si le poêle est déjà installé, enlevez la devanture, la 7. Détachez les 2 supports de brûleur du brûleur fenêtre, les bûches et panneaux de céramique.
  • Page 6 11. À l’aide de la lame d’un petit tournevis ou autre 15. À l’aide de la lame plate d’un petit tourvenis, objet similaire, soulevez le capuchon de plastique dévissez la vis de réglage de pression d’admission. couvrant la vis de réglage de pression sur le devant Fixez un manomètre à...