CAUTION
Do not use anything other than the correct capacity breaker and fuse. Using fuse, wire or
copper wire with too large capacity may cause a risk of malfunction or fire
After wiring is complete, make sure again that there is no tension on the connections, and attach the cover
onto the control box in the reverse order removal. Also, seal any openings created from wiring into the air
handler. This will prevent air leakage.
CAUTION
Wire the power supply so that no tension is imparted. Otherwise disconnection, heating or
fire may result.
IMPORTANT
Attach shielding ground on the outdoor unit's ground terminal.
If the remote controller cable exceeds 10 m [32 ft.], use a 1.25 mm
exceeded portion, and add that exceeded position to within 200 m [656 ft].
@