Connector powered (error code 0008)
The connector is powered when it should not be or is not powered when it should be.
Inform the technical service of the incident.
Energy meter communication fault (error code 0016)
The internal communication with the energy meter is not correct, possibly due to a trip of the protections. Proceed
to check the electric installation with a qualified personnel to check if protections have tripped.
If the protections have not tripped, notify the incident to the technical service.
RFID communication fault (error code 0032)
There is an anomaly with the internal communication with the card reader.
Inform the technical service of the incident.
DC current leak (error code 0128)
Depending on the model, charging stations can have a DC current leak sensor for charging. A leak in the current
that causes the alarm to trigger originates from the electric vehicle that is being charged; thus it is not an alarm for
the recharging station, rather the charge is stopped for safety reasons.
The maximum admissible limit for DC current leaks is exceeded.
Charging sequence fault (error code 0256)
Incorrect charging sequence or disconnection of the vehicle during charging. The alarm disappears upon
completing the session.
Maximum permitted charge current (error code 0512)
The vehicle has not respected the maximum charge current allowed during a maximum established time.
The alarm will disappear upon completion of the charge session of the electric vehicle causing the alarm.