INSTALLATION MANUAL
- If more than one device must be connected to the power supply
ensure that the total sum of the power absorbed by the devices (check
the plate data shown on the product label) does not exceed the
maximum power permitted by the Converter.
- DOMUS Line guarantees the product only if powered with a Converter
supplied by us.
HOW DOES THE DIVA-SUNCITY TLD (TouchLed-Dimmer) WORK?
After having given tension to the appliance, the electronic switch TLD,
will make an auto-test of regulation of the duration of around
20 seconds. Then it will send a series of flashes at the end of which the
DIVA-SUNCITY TLD will be ready to the use.
The turning on and off of the instrument simply happens with the rapid
touch of the sensitive switch TLD, while a long touch regulates the
intensity of the light increasing it or decreasing it. A short flash of the
TLD indicates the attainment of the maximum brightness.
The level of brightness obtained will be memorized up to the following
regulation.
The DIVA-SUNCITY TLD is provided with function "night-light" that
means a signalling light of the TLD that is activated only when the LEDs
are off. With normal or high light environment, the TLD issues a little
light, while with low or null light environment the TLD issues a more
intense light. During the operation of the LEDs, the light issued by the
TLD will be proportional to the regulation selected for them.
The function "night-light" can be disconnected or inserted with a long
touch on the TLD of 15 seconds, at the end of which the disconnection
of the function will be indicated with 2 little flashes, or the insertion
from 3 fast flashes.
The instrument is provided with a safety program that turns off the
DIVA-SUNCITY TLD after 18 hours of continuous operation.
This device must be connected directly to the electricity power supply
and must never be connected downstream of other electronic switches,
or near to electromagnetic sources.
EN
HOW DOES DIVA-SUNCITY IFR WORK?
The sensor IFR detects temperature changes combined with the
movement of people, animals and objects with a temperature of 36°C,
within the range as indicated in figure 8. In this case the sensor is
activated and turns on the device, which remains in operation for
approximately 30 seconds. After that, if no other changes are detected,
it turns off automatically.
The DIVA-SUNCITY IFR functions normally 40 seconds after it is first
switched on. During the 40-second start-up phase, the sensor
automatically sets up the device by detecting the installation
conditions. This is why it is necessary to wait until the procedure is
completed before using the device normally.
Detection field must not be obstructed by shelves or object positioned
too close of the sensor (fig.7)
The device must not be installed with the sensor close to
electromagnetic sources or heat sources, and must not be exposed to
direct light.
Significant changes in temperature, or the movement of objects within
the sensor detection "cone" caused, for example, by air conditioning
units, fans, smoke and steam, may stop the sensor device from
functioning properly.
WARNING:
The Led MODULE, the power supply cable or any switch used, are not
replaceable, therefore in case of damage the device must be entirely
substituted.
WARRANTY:
The warranty on the device is valid only if powered by a power supply
provided by DOMUS Line. The warranty's general terms and conditions
for this device are available at www.domusline.com
CAUTION
USE ONLY 24Vdc CLASS 2 POWER UNIT
USE ONLY 12Vdc CLASS 2 POWER UNIT
TO REDUCE THE RISK OF FIRE DO NOT INSTALL CLOSER THAN 10mm TO
THE CABINET WALL OR IN A COMPARTMENT SMALLER THAN 300mm BY
300mm

Publicité

loading

Ce manuel est également adapté pour:

Suncity collection