A) Scope of the device
Universal electronic board intended for the control of 2 motors fed by 24Vcc voltage and aimed for the automation of a swing gate. In case of
single-wing gate, use the output M2 and place the Dip switch 3 = ON.
B) Usage limitations
Caution: Before operating the electronic unit make sure the following operations have been carried out.
Note 1 - Read carefully the whole technical documentation supplied.
Note 2 - The electronic unit must be installed by qualified personnel only. The installation engineer must hav e the necessary technical and
professional qualification.
Note 3 - The power supply connected to the unit is to be 230 Vac +/- 10%.
Note 4 - The neutral (N) pole of power supply must be unipotential to the ground.
Note 5 - All safety rules for installation of electric and electronic devices are to be compulsory respected.
Note 6 - The main power must be supplied by an efficient differential switch tested and calibrated in conformity with the applicable rules.
Note 7 - Before starting the gate, suitably adjust the push exerted by wings so that it is not more than the one required by rules and anyway not such
to provoke damages in case of collision against things, people or animals.
Note 8 - The equipment is to be applied only for the use it was intended (see point A). All other use is to be considered improper and therefore
dangerous.
Note 9 - Before handling on the electronic unit, inside the box in which it is housed, check the main power has been cut off.
Note 10 - Do not handle the unit with wet/damp hand or feet.
Note 11 - Do not let the unit exposed to weather (rain, snow, etc.).
Note 12 - Do not allow any children or unqualified persons to touch the unit.
Note 13 - The electronic unit is to be placed in the box supplied.
Note 14 - The plastic material used for the box is not self-extinguishing. Therefore it must be installed in a well aired place far from any objects or
elements that can cause fire.
Note 15 - The ordinary maintenance of electronic unit is to be executed by qualified staff every 6 months.
Note 16 - For a correct working of the unit the length of wires connected to it is not to be more than 10 metres.
Note 17 - Install the equipment at a height not less than 1,5 metres to avoid children handling it.
Caution:
Failure to respect the above listed norms can cause damage to persons, animals or objects. The manufacturer can in no way
be held responsible for such damages.