Tightness inspection
Hoses check
Make sure that connecting hoses (1) are in a good condition
and correctly 昀椀xed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible clogging
along the hose, in the inlet and on the ba昀툀e plate inside the
昀椀ltering chamber.
To clean, scrape the inlet (2) from the outside to remove
deposits.
Filtering chamber gasket check
Make sure that the container (2) is tight with the 昀椀lter chamber
(3).
Replace the dust container gasket (1) or the liquid container
gasket (4) if it is not tight, or if it is torn, cut, etc.